Purpose: To assess the performance and the reproducibility of ultrasound-guided attenuation parameter (UGAP) and two-dimensional shear wave elastography (2D-SWE) in patients with biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD). Methods: This study included consecutive adult patients with MASLD who underwent ultrasound with UGAP, 2D-SWE and percutaneous liver biopsy. The median values of 12 consecutive UGAP measurements were acquired by two independent radiologists (R1 and R2). Hepatic steatosis was graded by liver biopsy as: (0) < 5%; (1) 5-33%; (2) > 33-66%; (3) > 66%. Areas under the curve (AUCs) were calculated to determine the diagnostic performance. Inter- and intra-observer reliability was assessed with intraclass correlation coefficient (ICC). Results: A hundred patients (median age 55.0 years old) with MASLD were prospectively enrolled. At histopathology, 70 and 42 patients had grade ≥ 2 and 3 steatosis, respectively. Median UGAP was 0.78 dB/cm/MHz (IQR/Med: 5.55%). For the diagnosis of grade ≥ 2 steatosis, the AUCs of UGAP were 0.828 (95% CI: 0.739, 0.896) for R1 and 0.779 (95% CI: 0.685, 0.856) for R2. The inter- and intra-operator reliability of UGAP were excellent, with an ICC of 0.92 (95% CI: 0.87-0.95) and 0.95 (95% CI: 0.92-0.96), respectively. The median liver stiffness was 6.76 kPa (IQR/Med: 16.30%). For the diagnosis of advanced fibrosis, 2D-SWE had an AUC of 0.862 (95% CI: 0.757, 0.934), and the optimal cutoff value was > 6.75 kPa with a sensitivity of 80.6% and a specificity of 75.7%. Conclusion: UGAP and 2D-SWE provide a good performance for the staging of steatosis and fibrosis in patients with MASLD with an excellent intra-operator reliability of UGAP.

Cannella, R., Agnello, F., Porrello, G., Spinello, A.U., Infantino, G., Pennisi, G., et al. (2024). Performance of ultrasound-guided attenuation parameter and 2D shear wave elastography in patients with metabolic dysfunction-associated steatotic liver disease. EUROPEAN RADIOLOGY [10.1007/s00330-024-11076-w].

Performance of ultrasound-guided attenuation parameter and 2D shear wave elastography in patients with metabolic dysfunction-associated steatotic liver disease

Cannella, Roberto
;
Porrello, Giorgia;Spinello, Alessandro Umberto;Pennisi, Grazia;Cabibi, Daniela;Petta, Salvatore;Bartolotta, Tommaso Vincenzo
2024-01-01

Abstract

Purpose: To assess the performance and the reproducibility of ultrasound-guided attenuation parameter (UGAP) and two-dimensional shear wave elastography (2D-SWE) in patients with biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD). Methods: This study included consecutive adult patients with MASLD who underwent ultrasound with UGAP, 2D-SWE and percutaneous liver biopsy. The median values of 12 consecutive UGAP measurements were acquired by two independent radiologists (R1 and R2). Hepatic steatosis was graded by liver biopsy as: (0) < 5%; (1) 5-33%; (2) > 33-66%; (3) > 66%. Areas under the curve (AUCs) were calculated to determine the diagnostic performance. Inter- and intra-observer reliability was assessed with intraclass correlation coefficient (ICC). Results: A hundred patients (median age 55.0 years old) with MASLD were prospectively enrolled. At histopathology, 70 and 42 patients had grade ≥ 2 and 3 steatosis, respectively. Median UGAP was 0.78 dB/cm/MHz (IQR/Med: 5.55%). For the diagnosis of grade ≥ 2 steatosis, the AUCs of UGAP were 0.828 (95% CI: 0.739, 0.896) for R1 and 0.779 (95% CI: 0.685, 0.856) for R2. The inter- and intra-operator reliability of UGAP were excellent, with an ICC of 0.92 (95% CI: 0.87-0.95) and 0.95 (95% CI: 0.92-0.96), respectively. The median liver stiffness was 6.76 kPa (IQR/Med: 16.30%). For the diagnosis of advanced fibrosis, 2D-SWE had an AUC of 0.862 (95% CI: 0.757, 0.934), and the optimal cutoff value was > 6.75 kPa with a sensitivity of 80.6% and a specificity of 75.7%. Conclusion: UGAP and 2D-SWE provide a good performance for the staging of steatosis and fibrosis in patients with MASLD with an excellent intra-operator reliability of UGAP.
2024
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
Cannella, R., Agnello, F., Porrello, G., Spinello, A.U., Infantino, G., Pennisi, G., et al. (2024). Performance of ultrasound-guided attenuation parameter and 2D shear wave elastography in patients with metabolic dysfunction-associated steatotic liver disease. EUROPEAN RADIOLOGY [10.1007/s00330-024-11076-w].
File in questo prodotto:
File Dimensione Formato  
s00330-024-11076-w.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 3.61 MB
Formato Adobe PDF
3.61 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/660313
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact