Time-resolved optical spectroscopies are emerging as a go-to technique for non-destructive testing of nanomaterials. Inspecting the thermal and mechanical properties of a mesoscale device requires achieving delay times beyond the ns timescale in a nanoscopy setup, potentially in a vibration polluted environment. These requirements constitute a major challenge for traditional pump-probe techniques based on moving mechanical delay lines and lock-in detection. Asynchronous optical sampling (ASOPS) and electronically controlled optical sampling (ECOPS), avoiding any moving mechanical parts, are good alternatives. However, their detection scheme is based on fast-balanced photodiodes, which, as a technology, are not as widespread, not as developed, and lack the performance of lock-in based detection. In this study, we introduce what we believe is a novel approach that integrates ASOPS/ECOPS and lock-in detection methodologies, eliminating the necessity for a reference signal and streamlining the optical configuration. By leveraging the strengths of each technique, our approach enhances sim- plicity and efficiency. The scheme is first validated against standard approaches in the frame of a beam-depletion measurement in a sum frequency experiment. It is then tested in a paradigmatic case study to inspect the mechanics of a single gold nanodisk, with dimensions in the 100 nm range, nanopatterned on a sapphire substrate. These results widen the range of applicability of time-resolved optical techniques as a nano-metrology tool to industrial settings.

Peli, S., Tognazzi, A., Franceschini, P., Gandolfi, M., Giannetti, C., Ferrini, G., et al. (2024). Simplifying asynchronous optical sampling: an experimental approach toward industrial integration exploiting lock-in acquisition. APPLIED OPTICS, 63(23) [10.1364/ao.525546].

Simplifying asynchronous optical sampling: an experimental approach toward industrial integration exploiting lock-in acquisition

Tognazzi, Andrea
Writing – Original Draft Preparation
;
2024-08-02

Abstract

Time-resolved optical spectroscopies are emerging as a go-to technique for non-destructive testing of nanomaterials. Inspecting the thermal and mechanical properties of a mesoscale device requires achieving delay times beyond the ns timescale in a nanoscopy setup, potentially in a vibration polluted environment. These requirements constitute a major challenge for traditional pump-probe techniques based on moving mechanical delay lines and lock-in detection. Asynchronous optical sampling (ASOPS) and electronically controlled optical sampling (ECOPS), avoiding any moving mechanical parts, are good alternatives. However, their detection scheme is based on fast-balanced photodiodes, which, as a technology, are not as widespread, not as developed, and lack the performance of lock-in based detection. In this study, we introduce what we believe is a novel approach that integrates ASOPS/ECOPS and lock-in detection methodologies, eliminating the necessity for a reference signal and streamlining the optical configuration. By leveraging the strengths of each technique, our approach enhances sim- plicity and efficiency. The scheme is first validated against standard approaches in the frame of a beam-depletion measurement in a sum frequency experiment. It is then tested in a paradigmatic case study to inspect the mechanics of a single gold nanodisk, with dimensions in the 100 nm range, nanopatterned on a sapphire substrate. These results widen the range of applicability of time-resolved optical techniques as a nano-metrology tool to industrial settings.
2-ago-2024
Settore ING-INF/02 - Campi Elettromagnetici
Peli, S., Tognazzi, A., Franceschini, P., Gandolfi, M., Giannetti, C., Ferrini, G., et al. (2024). Simplifying asynchronous optical sampling: an experimental approach toward industrial integration exploiting lock-in acquisition. APPLIED OPTICS, 63(23) [10.1364/ao.525546].
File in questo prodotto:
File Dimensione Formato  
Simplifying asynchronous optical sampling an experimental approach toward industrial integration exploiting lock-in acquisition.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2.71 MB
Formato Adobe PDF
2.71 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/649233
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact