It has long been established that UVC light is a very effective method for inactivating pathogens in a fluid, yet the application of UVC irradiation to modern biotechnological processes is limited by the intrinsic short penetration distance of UVC light in optically dense protein solutions. This experimental and numerical study establishes that irradiating a fluid flowing continuously in a microfluidic capillary system, in which the diameter of the capillary is tuned to the depth of penetration of UVC light, uniquely treats the whole volume of the fluid to UVC light, resulting in fast and effective inactivation of pathogens, with particular focus to virus particles. This was demonstrated by inactivating human herpes simplex virus type-1 (HSV-1, a large enveloped virus) on a dense 10% fetal calf serum solution in a range of fluoropolymer capillary systems, including a 0.75mm and 1.50mm internal diameter capillaries and a high-throughput MicroCapillary Film with mean hydraulic diameter of 206μm. Up to 99.96% of HSV-1 virus particles were effectively inactivated with a mean exposure time of up to 10s, with undetectable collateral damage to solution proteins. The kinetics of virus inactivation matched well the results from a new mathematical model that considers the parabolic flow profile in the capillaries, and showed the methodology is fully predictable and scalable and avoids both the side effect of UVC light to proteins and the dilution of the fluid in current tubular UVC inactivation systems. This is expected to speed up the industrial adoption of non-invasive UVC virus inactivation in clinical biotechnology and biomanufacturing of therapeutic molecules.

Ren Y., Crump C.M., Mackley M.M., Li Puma G., Reis N.M. (2016). Photo inactivation of virus particles in microfluidic capillary systems. BIOTECHNOLOGY AND BIOENGINEERING, 113(7), 1481-1492 [10.1002/bit.25912].

Photo inactivation of virus particles in microfluidic capillary systems

Li Puma G.;
2016-07-01

Abstract

It has long been established that UVC light is a very effective method for inactivating pathogens in a fluid, yet the application of UVC irradiation to modern biotechnological processes is limited by the intrinsic short penetration distance of UVC light in optically dense protein solutions. This experimental and numerical study establishes that irradiating a fluid flowing continuously in a microfluidic capillary system, in which the diameter of the capillary is tuned to the depth of penetration of UVC light, uniquely treats the whole volume of the fluid to UVC light, resulting in fast and effective inactivation of pathogens, with particular focus to virus particles. This was demonstrated by inactivating human herpes simplex virus type-1 (HSV-1, a large enveloped virus) on a dense 10% fetal calf serum solution in a range of fluoropolymer capillary systems, including a 0.75mm and 1.50mm internal diameter capillaries and a high-throughput MicroCapillary Film with mean hydraulic diameter of 206μm. Up to 99.96% of HSV-1 virus particles were effectively inactivated with a mean exposure time of up to 10s, with undetectable collateral damage to solution proteins. The kinetics of virus inactivation matched well the results from a new mathematical model that considers the parabolic flow profile in the capillaries, and showed the methodology is fully predictable and scalable and avoids both the side effect of UVC light to proteins and the dilution of the fluid in current tubular UVC inactivation systems. This is expected to speed up the industrial adoption of non-invasive UVC virus inactivation in clinical biotechnology and biomanufacturing of therapeutic molecules.
1-lug-2016
Ren Y., Crump C.M., Mackley M.M., Li Puma G., Reis N.M. (2016). Photo inactivation of virus particles in microfluidic capillary systems. BIOTECHNOLOGY AND BIOENGINEERING, 113(7), 1481-1492 [10.1002/bit.25912].
File in questo prodotto:
File Dimensione Formato  
Biotech Bioengineering - 2015 - Ren - Photo inactivation of virus particles in microfluidic capillary systems.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 1.57 MB
Formato Adobe PDF
1.57 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Ren_et_al_B&B_Revised_clean-As_accepted.pdf

accesso aperto

Tipologia: Post-print
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/646699
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact