Partial discharges (PD) are localized breakdowns in the insulation within high-voltage (HV) equipment and can be a warning sign of potential future failure. Regular PD monitoring through preventive maintenance is essential to the reliability of many expensive HV apparatuses. Hence, the purpose of this work is to assess the performance of a novel class of multi-turn inductive loop sensors based on printed circuit board (PCB) to detect PD in free space. Based on their topology, three distinct inductive sensors, named meander, non-spiral, and spiral, are evaluated towards detecting in-lab corona, internal, and surface PDs. Through simulations and measurements, the low-frequency lumped-element circuit model for each of the three magnetic field probes was extracted. Experimental PRPD patterns showed that the three evaluated inductive loops could be effectively applied for online monitoring and recognition of PDs. The experimental results show that the single PD pulses detected by the three sensors have a typical PD pulse shape that is a damped sinusoidal function with frequency spectra spanning from 14.84 MHz to 46 MHz. The spiral sensor yielded the maximum sensitivity, while the meander topology produced the lowest.

Antonino Imburgia, Sinda Kaziz, Pietro Romano, Denis Flandre, Giovanni Artale, Giuseppe Rizzo, et al. (2024). Printed-Board Inductive Loop Topologies Performance for Partial Discharges Detection. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS.

Printed-Board Inductive Loop Topologies Performance for Partial Discharges Detection

Antonino Imburgia
Writing – Original Draft Preparation
;
Sinda Kaziz;Pietro Romano
Supervision
;
Giovanni Artale;Fabio Viola;Guido Ala
Supervision
;
2024-04-02

Abstract

Partial discharges (PD) are localized breakdowns in the insulation within high-voltage (HV) equipment and can be a warning sign of potential future failure. Regular PD monitoring through preventive maintenance is essential to the reliability of many expensive HV apparatuses. Hence, the purpose of this work is to assess the performance of a novel class of multi-turn inductive loop sensors based on printed circuit board (PCB) to detect PD in free space. Based on their topology, three distinct inductive sensors, named meander, non-spiral, and spiral, are evaluated towards detecting in-lab corona, internal, and surface PDs. Through simulations and measurements, the low-frequency lumped-element circuit model for each of the three magnetic field probes was extracted. Experimental PRPD patterns showed that the three evaluated inductive loops could be effectively applied for online monitoring and recognition of PDs. The experimental results show that the single PD pulses detected by the three sensors have a typical PD pulse shape that is a damped sinusoidal function with frequency spectra spanning from 14.84 MHz to 46 MHz. The spiral sensor yielded the maximum sensitivity, while the meander topology produced the lowest.
2-apr-2024
Settore ING-IND/31 - Elettrotecnica
Antonino Imburgia, Sinda Kaziz, Pietro Romano, Denis Flandre, Giovanni Artale, Giuseppe Rizzo, et al. (2024). Printed-Board Inductive Loop Topologies Performance for Partial Discharges Detection. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS.
File in questo prodotto:
File Dimensione Formato  
Printed Board Inductive Antennas Performance for the Detection of Different Partial Discharges.pdf

accesso aperto

Tipologia: Pre-print
Dimensione 2.54 MB
Formato Adobe PDF
2.54 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/644715
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact