The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+-> e+gamma\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu <^>+ \rightarrow {\textrm{e}}<^>+ \upgamma $$\end{document} decay down to similar to 6x10-14\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim 6 \times 10<^>{-14}$$\end{document} almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

K. Afanaciev, A. M. Baldini, S. Ban, V. Baranov, H. Benmansour, M. Biasotti, et al. (2024). Operation and performance of the MEG II detector. EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 84(2) [10.1140/epjc/s10052-024-12415-3].

Operation and performance of the MEG II detector

G. Boca;G. Chiarello;G. Gallucci;
2024-02-26

Abstract

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+-> e+gamma\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu <^>+ \rightarrow {\textrm{e}}<^>+ \upgamma $$\end{document} decay down to similar to 6x10-14\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim 6 \times 10<^>{-14}$$\end{document} almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
26-feb-2024
K. Afanaciev, A. M. Baldini, S. Ban, V. Baranov, H. Benmansour, M. Biasotti, et al. (2024). Operation and performance of the MEG II detector. EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 84(2) [10.1140/epjc/s10052-024-12415-3].
File in questo prodotto:
File Dimensione Formato  
s10052-024-12415-3.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 8.34 MB
Formato Adobe PDF
8.34 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/639814
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact