Purpose: To assess the safety and effectiveness of a rotational mechanical atherothrombectomy device in patients with symptomatic iliac limb occlusion after abdominal endovascular aneurysm repair (EVAR). Materials and methods: A retrospective analysis was conducted on patients who underwent rotational mechanical thrombectomy using the Rotarex S device for symptomatic acute, subacute, or chronic graft limb thrombosis at 5 vascular centers between 2017 and 2021. This study comprised 23 male patients with a mean age of 74.5 years (SD ± 7.2) at the time of the procedure. The clinical presentation of the patients varied, with 1 patient experiencing acute limb ischemia and 11 patients (47.8%) experiencing disabling intermittent claudication. The remaining patients developed chronic limb-threatening ischemia after iliac limb occlusion. Early outcomes included technical success, postprocedural complications, and periprocedural mortality. Follow-up evaluations encompassed primary patency, patient survival, freedom from reintervention, and the need for surgical conversion. Results: Technical success was achieved in all cases, with no occurrences of distal embolization during or after the procedure, and no periprocedural deaths were reported. Endograft relining was performed in 82.6% of patients to establish a new, nonthrombogenic surface within the graft. Over a median follow-up period of 8 months (interquartile range, 3-16 months), 2 patients experienced iliac limb reocclusion. No deaths or other reinterventions occurred during the observational follow-up period. Conclusions: Rotational mechanical thrombectomy for iliac limb occlusion after EVAR appears to be both safe and effective. This technique may uncover intraluminal defects contributing to graft occlusion and enable their resolution within the same procedure.
Simonte G., Isernia G., Pecoraro F., Antonello M., Guzzardi G., Dinoto E., et al. (2023). Rotational Mechanical Thrombectomy to Treat Iliac Limb Occlusion after Endovascular Aortic Aneurysm Repair: The Rotational Mechanical Thrombectomy Italian Study. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 35(1), 25-31 [10.1016/j.jvir.2023.09.022].
Rotational Mechanical Thrombectomy to Treat Iliac Limb Occlusion after Endovascular Aortic Aneurysm Repair: The Rotational Mechanical Thrombectomy Italian Study
Pecoraro F.;Dinoto E.;
2023-09-28
Abstract
Purpose: To assess the safety and effectiveness of a rotational mechanical atherothrombectomy device in patients with symptomatic iliac limb occlusion after abdominal endovascular aneurysm repair (EVAR). Materials and methods: A retrospective analysis was conducted on patients who underwent rotational mechanical thrombectomy using the Rotarex S device for symptomatic acute, subacute, or chronic graft limb thrombosis at 5 vascular centers between 2017 and 2021. This study comprised 23 male patients with a mean age of 74.5 years (SD ± 7.2) at the time of the procedure. The clinical presentation of the patients varied, with 1 patient experiencing acute limb ischemia and 11 patients (47.8%) experiencing disabling intermittent claudication. The remaining patients developed chronic limb-threatening ischemia after iliac limb occlusion. Early outcomes included technical success, postprocedural complications, and periprocedural mortality. Follow-up evaluations encompassed primary patency, patient survival, freedom from reintervention, and the need for surgical conversion. Results: Technical success was achieved in all cases, with no occurrences of distal embolization during or after the procedure, and no periprocedural deaths were reported. Endograft relining was performed in 82.6% of patients to establish a new, nonthrombogenic surface within the graft. Over a median follow-up period of 8 months (interquartile range, 3-16 months), 2 patients experienced iliac limb reocclusion. No deaths or other reinterventions occurred during the observational follow-up period. Conclusions: Rotational mechanical thrombectomy for iliac limb occlusion after EVAR appears to be both safe and effective. This technique may uncover intraluminal defects contributing to graft occlusion and enable their resolution within the same procedure.File | Dimensione | Formato | |
---|---|---|---|
142_2024_ro.me.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
958.96 kB
Formato
Adobe PDF
|
958.96 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.