The cluster counting/timing technique in a drift chamber allows to have a bias free impact parameter estimate. The application of this technique requires to measuring and counting the arrival times of each individual ionization cluster to a sense wire. In a Helium based gas mixture the rise time of the signal from a cluster is approximately 1 ns, therefore a readout electronic front-end with high linearity, low distortion and sufficiently high bandwidth is required. Furthermore, it would be useful for the readout electronics to be able to easily adapt its gain to the detector's operating point. The use of a variable gain amplifier (VGA) allows to meet the needs arising from the changed operating conditions of the detector. The market offers components capable of satisfying all these needs with dimensions compatible with high-density drift chambers. A high linear, low distortion, remotely controllable, about 1GHz bandwidth and compact VGA is presented together with the measurements performed.

Panareo M., Chiarello G., Cuna F., Corvaglia A., Grancagnolo F. (2023). A variable gain front-end electronics for drift chambers. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1046 [10.1016/j.nima.2022.167822].

A variable gain front-end electronics for drift chambers

Chiarello G.
Secondo
;
2023-01-11

Abstract

The cluster counting/timing technique in a drift chamber allows to have a bias free impact parameter estimate. The application of this technique requires to measuring and counting the arrival times of each individual ionization cluster to a sense wire. In a Helium based gas mixture the rise time of the signal from a cluster is approximately 1 ns, therefore a readout electronic front-end with high linearity, low distortion and sufficiently high bandwidth is required. Furthermore, it would be useful for the readout electronics to be able to easily adapt its gain to the detector's operating point. The use of a variable gain amplifier (VGA) allows to meet the needs arising from the changed operating conditions of the detector. The market offers components capable of satisfying all these needs with dimensions compatible with high-density drift chambers. A high linear, low distortion, remotely controllable, about 1GHz bandwidth and compact VGA is presented together with the measurements performed.
11-gen-2023
Panareo M., Chiarello G., Cuna F., Corvaglia A., Grancagnolo F. (2023). A variable gain front-end electronics for drift chambers. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1046 [10.1016/j.nima.2022.167822].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900222011147-main.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/618886
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact