In Italy, a large part of the buildings classified as historical-artistic heritage is in a state of degradation and requires urgent interventions. Among the needs, a reduction in the high energy consumption and an improvement of the indoor comfort are mandatory. The case study of the "Ex Institute of Zoology of Palermo" shows how it is possible to achieve a reduction in energy consumption and preserve the building's historicity through the estimation of energy loads and the subsequent processing. To quantify the energy savings of the structure, it was necessary to follow a few steps, namely an inspection of the building and an evaluation of its consumption. To elaborate a correct energy analysis, the thermal conductance was calculated by considering measurements over a period of 60 days and proceeding with the calculation of the transmittance. The resulting data are imported in the energy model developed with the TERMUS BIM software. In the case study, a potential energy saving equal to 35% of the current energy consumption can be avoided by replacing the lamps with LED ones, installing photovoltaic panels, replacing the heat pumps with a centralized system and the current fixtures with double thermal break fixtures. These interventions are implemented in compliance with the architectural peculiarities.

Curto D., Franzitta V., Guercio A., Mantegna M., Milone D. (2023). Energy Efficiency in Historic Architecture: The “Ex Institute of Zoology and Comparative Anatomy” in Palermo. APPLIED SCIENCES, 13(15) [10.3390/app13158882].

Energy Efficiency in Historic Architecture: The “Ex Institute of Zoology and Comparative Anatomy” in Palermo

Curto D.;Franzitta V.;Guercio A.
;
Milone D.
2023-08-01

Abstract

In Italy, a large part of the buildings classified as historical-artistic heritage is in a state of degradation and requires urgent interventions. Among the needs, a reduction in the high energy consumption and an improvement of the indoor comfort are mandatory. The case study of the "Ex Institute of Zoology of Palermo" shows how it is possible to achieve a reduction in energy consumption and preserve the building's historicity through the estimation of energy loads and the subsequent processing. To quantify the energy savings of the structure, it was necessary to follow a few steps, namely an inspection of the building and an evaluation of its consumption. To elaborate a correct energy analysis, the thermal conductance was calculated by considering measurements over a period of 60 days and proceeding with the calculation of the transmittance. The resulting data are imported in the energy model developed with the TERMUS BIM software. In the case study, a potential energy saving equal to 35% of the current energy consumption can be avoided by replacing the lamps with LED ones, installing photovoltaic panels, replacing the heat pumps with a centralized system and the current fixtures with double thermal break fixtures. These interventions are implemented in compliance with the architectural peculiarities.
1-ago-2023
Settore ING-IND/11 - Fisica Tecnica Ambientale
Curto D., Franzitta V., Guercio A., Mantegna M., Milone D. (2023). Energy Efficiency in Historic Architecture: The “Ex Institute of Zoology and Comparative Anatomy” in Palermo. APPLIED SCIENCES, 13(15) [10.3390/app13158882].
File in questo prodotto:
File Dimensione Formato  
applsci 2023 - Energy Efficiency Ex Institute Zoology.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 2.93 MB
Formato Adobe PDF
2.93 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/606193
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact