Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated into wrist-worn commercial products which presents significant advantages in terms of cost and dimensions. PPG-based devices, despite their ability to detect multiple cardiovascular parameters, are affected by several influencing conditions that depend both on technological or environmental variables, and on intra- and inter-subject variability that influences the whole measurement chain and reliability, hindering an objective characterization of PPG devices. Plus, the lack of standardization for data collection and processing leads to the lack of generalizability and reproducibility of results, preventing the full exploitation of the potential prognostic capacity of this technology. Thus, this review aims not only to summarize the main influencing parameters of PPG technology, which should be addressed when testing the sensor, but also to suggest tentative guidelines for a possible future standardization initiative.

Scardulla F., Cosoli G., Spinsante S., Poli A., Iadarola G., Pernice R., et al. (2023). Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review. MEASUREMENT, 218, 113150 [10.1016/j.measurement.2023.113150].

Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review

Scardulla F.
Primo
;
Pernice R.;Busacca A.;Pasta S.;D'Acquisto L.
Ultimo
2023-06-01

Abstract

Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated into wrist-worn commercial products which presents significant advantages in terms of cost and dimensions. PPG-based devices, despite their ability to detect multiple cardiovascular parameters, are affected by several influencing conditions that depend both on technological or environmental variables, and on intra- and inter-subject variability that influences the whole measurement chain and reliability, hindering an objective characterization of PPG devices. Plus, the lack of standardization for data collection and processing leads to the lack of generalizability and reproducibility of results, preventing the full exploitation of the potential prognostic capacity of this technology. Thus, this review aims not only to summarize the main influencing parameters of PPG technology, which should be addressed when testing the sensor, but also to suggest tentative guidelines for a possible future standardization initiative.
giu-2023
Scardulla F., Cosoli G., Spinsante S., Poli A., Iadarola G., Pernice R., et al. (2023). Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review. MEASUREMENT, 218, 113150 [10.1016/j.measurement.2023.113150].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0263224123007145-main.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2.18 MB
Formato Adobe PDF
2.18 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/600394
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact