The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symmetry index progressively improved from the pre-op with socket-type (1.14) to the last follow-up (1.04). Step width after osseointegration surgery was half of the pre-op. Hip flexion-extension range significantly improved at follow-ups while frontal and transverse plane rotations decreased (p < 0.001). Pelvis anteversion, obliquity, and rotation also decreased over time (p < 0.001). Spatiotemporal and gait kinematics improved after osseointegration surgery. One year after surgery, symmetry indices were close to non-pathological gait and gait compensation was sensibly decreased. From a functional point of view, osseointegration surgery could be a valid solution in patients with transfemoral amputation facing issues with traditional socket-type prosthesis.

Stefano Di Paolo, Giuseppe Barone, Domenico Alesi, Agostino Igor Mirulla, Emanuele Gruppioni, Stefano Zaffagnini, et al. (2023). Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis. SENSORS, 23(8) [10.3390/s23084037].

Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis

Agostino Igor Mirulla;
2023-04-17

Abstract

The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symmetry index progressively improved from the pre-op with socket-type (1.14) to the last follow-up (1.04). Step width after osseointegration surgery was half of the pre-op. Hip flexion-extension range significantly improved at follow-ups while frontal and transverse plane rotations decreased (p < 0.001). Pelvis anteversion, obliquity, and rotation also decreased over time (p < 0.001). Spatiotemporal and gait kinematics improved after osseointegration surgery. One year after surgery, symmetry indices were close to non-pathological gait and gait compensation was sensibly decreased. From a functional point of view, osseointegration surgery could be a valid solution in patients with transfemoral amputation facing issues with traditional socket-type prosthesis.
17-apr-2023
Settore ING-IND/15 - Disegno E Metodi Dell'Ingegneria Industriale
Stefano Di Paolo, Giuseppe Barone, Domenico Alesi, Agostino Igor Mirulla, Emanuele Gruppioni, Stefano Zaffagnini, et al. (2023). Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis. SENSORS, 23(8) [10.3390/s23084037].
File in questo prodotto:
File Dimensione Formato  
sensors-23-04037.pdf

accesso aperto

Descrizione: articolo completo
Tipologia: Versione Editoriale
Dimensione 4.13 MB
Formato Adobe PDF
4.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/598794
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact