This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installa-tion. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge rela-tionship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge curve obtained based on the laboratory tests was verified using field data. The results revealed that the proposed portable flume could be used accurately to determine the flow through an unlined ditch. Practical suggestions were proposed to determine the distinguish-ing condition curve.

Bijankhan M., Teymourkhani A., Ferro V. (2022). Portable central baffle flume. JOURNAL OF AGRICULTURAL ENGINEERING, 53(2) [10.4081/jae.2022.1339].

Portable central baffle flume

Ferro V.
2022-01-01

Abstract

This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installa-tion. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge rela-tionship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge curve obtained based on the laboratory tests was verified using field data. The results revealed that the proposed portable flume could be used accurately to determine the flow through an unlined ditch. Practical suggestions were proposed to determine the distinguish-ing condition curve.
2022
Bijankhan M., Teymourkhani A., Ferro V. (2022). Portable central baffle flume. JOURNAL OF AGRICULTURAL ENGINEERING, 53(2) [10.4081/jae.2022.1339].
File in questo prodotto:
File Dimensione Formato  
2022_Bijankhan_et_al_jae-53-2-1339.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 1.12 MB
Formato Adobe PDF
1.12 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/581495
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact