Introduction: Malignant pleural effusion (PE) is a rather frequent complication of several intrathoracic and extrathoracic tumors and has an incidence of about 660 patients per million inhabitants per year. Materials and methods: We retrospectively studied (2000 to 2018) the utility of US guided percutaneous puncture (PP) of PE, in the diagnosis/therapy of 121 patients (67 women and 54 men) with PE and suspected malignant neoplasm, mean age 52 years (39-78 years), Results: The diagnostic accuracy of the US guided PP fluid examination, (diagnoses of malignant PE), was 91.7% (111/121), with sensitivity of 89.5% (86/96) and specificity of 100%. (25/25). 10 patients did not have confirmation of malignant PE with US guided PP; the malignancy diagnosis was obtained by biopsy with other surgical procedure. Conclusions: The use of chest US has allowed us to reduce procedure time, hospital stay, with a significant reduction in healthcare costs, and to obtain a particularly high diagnostic accuracy with good patient compliance. We did not observe major complications during US guided PP; minor complications were found in 16.9% (14 cases) with the presence of mild chest pain.

Geraci G., Cocchiara G., Palazzolo M., Cajozzo A. (2022). ULTRASOUND (US) GUIDED DIAGNOSTIC PROCEDURES AND MALIGNANT PLEURAL EFFUSIONS. ACTA MEDICA MEDITERRANEA, 38(4), 2349-2350 [10.19193/0393-6384_2022_4_357].

ULTRASOUND (US) GUIDED DIAGNOSTIC PROCEDURES AND MALIGNANT PLEURAL EFFUSIONS

Geraci G.;
2022-05-20

Abstract

Introduction: Malignant pleural effusion (PE) is a rather frequent complication of several intrathoracic and extrathoracic tumors and has an incidence of about 660 patients per million inhabitants per year. Materials and methods: We retrospectively studied (2000 to 2018) the utility of US guided percutaneous puncture (PP) of PE, in the diagnosis/therapy of 121 patients (67 women and 54 men) with PE and suspected malignant neoplasm, mean age 52 years (39-78 years), Results: The diagnostic accuracy of the US guided PP fluid examination, (diagnoses of malignant PE), was 91.7% (111/121), with sensitivity of 89.5% (86/96) and specificity of 100%. (25/25). 10 patients did not have confirmation of malignant PE with US guided PP; the malignancy diagnosis was obtained by biopsy with other surgical procedure. Conclusions: The use of chest US has allowed us to reduce procedure time, hospital stay, with a significant reduction in healthcare costs, and to obtain a particularly high diagnostic accuracy with good patient compliance. We did not observe major complications during US guided PP; minor complications were found in 16.9% (14 cases) with the presence of mild chest pain.
20-mag-2022
Geraci G., Cocchiara G., Palazzolo M., Cajozzo A. (2022). ULTRASOUND (US) GUIDED DIAGNOSTIC PROCEDURES AND MALIGNANT PLEURAL EFFUSIONS. ACTA MEDICA MEDITERRANEA, 38(4), 2349-2350 [10.19193/0393-6384_2022_4_357].
File in questo prodotto:
File Dimensione Formato  
document_1.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 181.66 kB
Formato Adobe PDF
181.66 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/580976
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact