Although aortic resection and end-to-end anastomosis are applied to repair ascending aortic aneurysm, there is a lack of information on the late risk of post-operative complications, such as aortic dissection and aneurysmal re-dilatation. It is recognized that altered hemodynamic forces exerted on an aortic wall play an important role on dissection and aneurysm formation. We present a case in which the hemodynamic forces were investigated prior and after repair of an ascending aorta treated by resection with end-to-end anastomosis and a bioprosthetic heart valve. Post-operative wall shear stress was redistributed uniformly along the vessel circumference, and this may suggest a reduced risk of complications near aortic root, but not exclude the re-dilatation of the ascending aorta.

Raffa G.M., Pasta S. (2020). Ascending Aorta Resection and End-to-End Anastomosis: Redistribution of Wall Shear Stress Induced by a Bioprosthetic Heart Valve. PROSTHESIS, 2(4), 297-303 [10.3390/prosthesis2040026].

Ascending Aorta Resection and End-to-End Anastomosis: Redistribution of Wall Shear Stress Induced by a Bioprosthetic Heart Valve

Pasta S.
2020-01-01

Abstract

Although aortic resection and end-to-end anastomosis are applied to repair ascending aortic aneurysm, there is a lack of information on the late risk of post-operative complications, such as aortic dissection and aneurysmal re-dilatation. It is recognized that altered hemodynamic forces exerted on an aortic wall play an important role on dissection and aneurysm formation. We present a case in which the hemodynamic forces were investigated prior and after repair of an ascending aorta treated by resection with end-to-end anastomosis and a bioprosthetic heart valve. Post-operative wall shear stress was redistributed uniformly along the vessel circumference, and this may suggest a reduced risk of complications near aortic root, but not exclude the re-dilatation of the ascending aorta.
2020
Raffa G.M., Pasta S. (2020). Ascending Aorta Resection and End-to-End Anastomosis: Redistribution of Wall Shear Stress Induced by a Bioprosthetic Heart Valve. PROSTHESIS, 2(4), 297-303 [10.3390/prosthesis2040026].
File in questo prodotto:
File Dimensione Formato  
prosthesis-02-00026-v2.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 1.66 MB
Formato Adobe PDF
1.66 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/578700
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact