A recursive method that eliminates +1 harmonics and their respective multiples from the output voltage of a cascaded H-bridge multilevel inverters with = 2 dc sources ( = 1, 2, 3,...) is proposed. It solves 2×2 linear systems with not singular matrices and always gives an exact solution with very low computational effort. Simulated results in three-phase five, nine, seventeen and thirty three level CHB inverters, and experimental results in five-level inverter demonstrate the validity of the method.
Buccella C., Cimoroni M., Cecati C., Di Tommaso A., Miceli R., Nevoloso C., et al. (2023). Recursive Selective Harmonic Elimination for Multilevel Inverters: Mathematical Formulation and Experimental Validation. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 11(2), 2178-2189 [10.1109/JESTPE.2022.3221154].
Recursive Selective Harmonic Elimination for Multilevel Inverters: Mathematical Formulation and Experimental Validation
Di Tommaso A.;Miceli R.;Nevoloso C.
;Schettino G.
2023-04-01
Abstract
A recursive method that eliminates +1 harmonics and their respective multiples from the output voltage of a cascaded H-bridge multilevel inverters with = 2 dc sources ( = 1, 2, 3,...) is proposed. It solves 2×2 linear systems with not singular matrices and always gives an exact solution with very low computational effort. Simulated results in three-phase five, nine, seventeen and thirty three level CHB inverters, and experimental results in five-level inverter demonstrate the validity of the method.File | Dimensione | Formato | |
---|---|---|---|
Recursive_Selective_Harmonic_Elimination_for_Multilevel_Inverters_Mathematical_Formulation_and_Experimental_Validation.pdf
accesso aperto
Tipologia:
Versione Editoriale
Dimensione
6.83 MB
Formato
Adobe PDF
|
6.83 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.