Purpose To assess the role of 2D-shear wave elastography (2D-SWE) in differentiating benign from malignant focal breast lesions (FBLs), providing new vendor-specific cutoff values. Methods 158 FBLs (size: 3.5-50 mm) detected in 151 women (age: 21-87 years) were prospectively evaluated by means 2D-SWE. For each lesion, an expert radiologist assessed US BI-RADS category and calculated the following four 2D-SWE parameters: (1) elasticity maximum (E-max); (2) mean elasticity (E-mean); (3) minimum elasticity (E-min); (4) elasticity ratio (E-ratio). US-guided core-biopsy was considered as standard of reference for all the FBLs classified as BI-RADS 4 or 5. For each 2D-SWE parameter, the optimal cutoff value for a diagnostic test was calculated using the Youden method. Diagnostic performance of the US BI-RADS and 2D-SWE parameters was calculated accordingly. Results 83/158 (52.5%) FBLs were benign and 75/158 (47.5%) were malignant. Statistically significant higher stiffness values were observed in malignant FBLs for all 2D-SWE parameters than in benign ones (p < 0.001). 2D-SWE cutoff values were 82.6 kPa, 66.0 kPa and 53.6 kPa, respectively, for E-max, E-mean, E-min and 330.8% for E-ratio. The 2D-SWE parameter showing the best diagnostic accuracy was E-max (85.44%). Considering US BI-RADS 3 (n = 60) and 4a (n = 32) FBLs, E-max and E-mean showed the best diagnostic accuracy (85.87% for both), without a statistically significant decrease in sensitivity (p = 0.7003 and p = 1, respectively). Conclusion Our study provides new vendor-specific cutoff values for 2D-SWE, suggesting its possible clinical use in the adjunctive assessment of category US-BI-RADS 3 and 4a breast masses.
Bartolotta, T.V., Orlando, A.A.M., Dimarco, M., Zarcaro, C., Ferraro, F., Cirino, A., et al. (2022). Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values. LA RADIOLOGIA MEDICA, 127(11), 1209-1220 [10.1007/s11547-022-01546-w].
Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values
Bartolotta, Tommaso Vincenzo;Orlando, Alessia Angela Maria;Dimarco, Mariangela;Zarcaro, Calogero;Ferraro, Fabiola;Cirino, Alessandra;Matranga, Domenica;Vieni, Salvatore;Cabibi, Daniela
2022-11-01
Abstract
Purpose To assess the role of 2D-shear wave elastography (2D-SWE) in differentiating benign from malignant focal breast lesions (FBLs), providing new vendor-specific cutoff values. Methods 158 FBLs (size: 3.5-50 mm) detected in 151 women (age: 21-87 years) were prospectively evaluated by means 2D-SWE. For each lesion, an expert radiologist assessed US BI-RADS category and calculated the following four 2D-SWE parameters: (1) elasticity maximum (E-max); (2) mean elasticity (E-mean); (3) minimum elasticity (E-min); (4) elasticity ratio (E-ratio). US-guided core-biopsy was considered as standard of reference for all the FBLs classified as BI-RADS 4 or 5. For each 2D-SWE parameter, the optimal cutoff value for a diagnostic test was calculated using the Youden method. Diagnostic performance of the US BI-RADS and 2D-SWE parameters was calculated accordingly. Results 83/158 (52.5%) FBLs were benign and 75/158 (47.5%) were malignant. Statistically significant higher stiffness values were observed in malignant FBLs for all 2D-SWE parameters than in benign ones (p < 0.001). 2D-SWE cutoff values were 82.6 kPa, 66.0 kPa and 53.6 kPa, respectively, for E-max, E-mean, E-min and 330.8% for E-ratio. The 2D-SWE parameter showing the best diagnostic accuracy was E-max (85.44%). Considering US BI-RADS 3 (n = 60) and 4a (n = 32) FBLs, E-max and E-mean showed the best diagnostic accuracy (85.87% for both), without a statistically significant decrease in sensitivity (p = 0.7003 and p = 1, respectively). Conclusion Our study provides new vendor-specific cutoff values for 2D-SWE, suggesting its possible clinical use in the adjunctive assessment of category US-BI-RADS 3 and 4a breast masses.File | Dimensione | Formato | |
---|---|---|---|
s11547-022-01546-w.pdf
Solo gestori archvio
Tipologia:
Versione Editoriale
Dimensione
1.58 MB
Formato
Adobe PDF
|
1.58 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.