The necessity to improve the energy saving potential of buildings is now a duty. European and national policies are being implemented to address the important decisions being made on this subject. For these reasons, several studies focus on this relevant topic. This paper review not only focusses on it but studies it in-depth. A commercial 3D simulation software was used to design a building sited in Palermo estimating the thermal losses before and after external envelope insulation. In particular, all the thermal bridges (TBs) were analysed with the finite element method (FEM) and mitigated with rock wool insulation. The paper shows the linear thermal transmittance difference and heat flux loss before and after TB mitigation. The results confirm the importance of installing an external insulation layer in the old building envelope. The linear thermal transmittance of TBs and the associated heat flux loss often decrease by more than 50%.
Curto D., Franzitta V., Guercio A., Martorana P. (2022). FEM Analysis: A Review of the Most Common Thermal Bridges and Their Mitigation [10.3390/en15072318].
FEM Analysis: A Review of the Most Common Thermal Bridges and Their Mitigation
Curto D.;Franzitta V.;Guercio A.
;
2022-04-01
Abstract
The necessity to improve the energy saving potential of buildings is now a duty. European and national policies are being implemented to address the important decisions being made on this subject. For these reasons, several studies focus on this relevant topic. This paper review not only focusses on it but studies it in-depth. A commercial 3D simulation software was used to design a building sited in Palermo estimating the thermal losses before and after external envelope insulation. In particular, all the thermal bridges (TBs) were analysed with the finite element method (FEM) and mitigated with rock wool insulation. The paper shows the linear thermal transmittance difference and heat flux loss before and after TB mitigation. The results confirm the importance of installing an external insulation layer in the old building envelope. The linear thermal transmittance of TBs and the associated heat flux loss often decrease by more than 50%.File | Dimensione | Formato | |
---|---|---|---|
energies-15-02318-v2.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Versione Editoriale
Dimensione
8.24 MB
Formato
Adobe PDF
|
8.24 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.