JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day (cpd), therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz (i.e. ∼1 cpd accidental background) in the default fiducial volume, above an energy threshold of 0.7 MeV

Abusleme A., Adam T., Ahmad S., Ahmed R., Aiello S., Akram M., et al. (2021). Radioactivity control strategy for the JUNO detector. JOURNAL OF HIGH ENERGY PHYSICS, 2021(11) [10.1007/JHEP11(2021)102].

Radioactivity control strategy for the JUNO detector

Buscemi M.;
2021-11-15

Abstract

JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day (cpd), therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz (i.e. ∼1 cpd accidental background) in the default fiducial volume, above an energy threshold of 0.7 MeV
15-nov-2021
Settore FIS/01 - Fisica Sperimentale
Abusleme A., Adam T., Ahmad S., Ahmed R., Aiello S., Akram M., et al. (2021). Radioactivity control strategy for the JUNO detector. JOURNAL OF HIGH ENERGY PHYSICS, 2021(11) [10.1007/JHEP11(2021)102].
File in questo prodotto:
File Dimensione Formato  
Abusleme2021_Article_RadioactivityControlStrategyFo.pdf

accesso aperto

Descrizione: articolo
Tipologia: Versione Editoriale
Dimensione 7.37 MB
Formato Adobe PDF
7.37 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/544930
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 13
social impact