In this paper the dynamic behavior of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed with the Simulink simulation tool (Matlab Inc.) It is composed of the induction generator, the shaft system, an aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phase fault is applied close to the wind turbine and cleared by disconnecting the faulty line. The rigorous implementation of the simulink model allowed the authors to evaluate the exact dependence of various electrical parameters for the induction generator on voltage stability. Furthermore, the effects of wind turbine mechanical construction and of grid parameters on voltage stability are also evaluated and discussed. For each parameter, the terminal voltage and the generator rotor speed for different fault-clearing times are drawn. Finally, the terminal voltage and the generator rotor speed obtained for a fifth order model of the induction generator are compared with those obtained for a third order model. The differences between the two models are discussed. The results will help to understand transient stability phenomena in wind farms.
Dusonchet, L., Telaretti, E. (2011). Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine. ELECTRIC POWER SYSTEMS RESEARCH, 81, 1308-1316 [10.1016/j.epsr.2011.01.016].
Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine
DUSONCHET, Luigi;TELARETTI, Enrico
2011-01-01
Abstract
In this paper the dynamic behavior of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed with the Simulink simulation tool (Matlab Inc.) It is composed of the induction generator, the shaft system, an aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phase fault is applied close to the wind turbine and cleared by disconnecting the faulty line. The rigorous implementation of the simulink model allowed the authors to evaluate the exact dependence of various electrical parameters for the induction generator on voltage stability. Furthermore, the effects of wind turbine mechanical construction and of grid parameters on voltage stability are also evaluated and discussed. For each parameter, the terminal voltage and the generator rotor speed for different fault-clearing times are drawn. Finally, the terminal voltage and the generator rotor speed obtained for a fifth order model of the induction generator are compared with those obtained for a third order model. The differences between the two models are discussed. The results will help to understand transient stability phenomena in wind farms.File | Dimensione | Formato | |
---|---|---|---|
Full paper (published).pdf
Solo gestori archvio
Descrizione: Articolo principale
Dimensione
769.44 kB
Formato
Adobe PDF
|
769.44 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.