The current transformer (CT) performance under distorted waveform conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency response approach for the evaluation of CT performance under distorted waveform conditions is not a reliable method.

Cataliotti, A., Di Cara, D., Emanuel, A.E., Nuccio, S. (2009). A Novel Approach to Current Transformer Characterization in the Presence of Harmonic Distortion. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 58 n. 5, 1446-1453.

A Novel Approach to Current Transformer Characterization in the Presence of Harmonic Distortion

CATALIOTTI, Antonio;DI CARA, Dario;NUCCIO, Salvatore
2009-01-01

Abstract

The current transformer (CT) performance under distorted waveform conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency response approach for the evaluation of CT performance under distorted waveform conditions is not a reliable method.
2009
Cataliotti, A., Di Cara, D., Emanuel, A.E., Nuccio, S. (2009). A Novel Approach to Current Transformer Characterization in the Presence of Harmonic Distortion. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 58 n. 5, 1446-1453.
File in questo prodotto:
File Dimensione Formato  
53755.pdf

Solo gestori archvio

Dimensione 710.74 kB
Formato Adobe PDF
710.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/53755
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 81
  • ???jsp.display-item.citation.isi??? 71
social impact