Primary PCI plus stent implantation is indicated for treatment of acute coronary syndrome. Technically, due to the difference in lumen diameter between vessel portions and stent size in some coronary arteries, post-expansion of the stent is usually necessary to match proximal reference diameter and optimize stent apposition. Incomplete stent apposition has been associated with increased risk of in stent restenosis (ISR) and stent thrombosis (1) despite new stent technologies have largely reduced this risk (2-3). Although new antiplatelet drugs showed a more rapid onset of action and a stronger effect (4-5), stent apposition remains an important risk factor for stent thrombosis. As stent post-dilatation is commonly performed, typically with large over-expansion in the setting of long tapering vessel segment. There is an increasing recognition that information with regard to the different stent model designs can have a critical impact on results
Simone Calcagno, V.S. (2021). Stent Oversizing or not-oversizing? An unresolved dilemma. MINERVA CARDIOLOGY AND ANGIOLOGY [10.23736/S2724-5683.20.05570-X].
Stent Oversizing or not-oversizing? An unresolved dilemma.
Vincenzo SucatoSecondo
Membro del Collaboration Group
;
2021-11-01
Abstract
Primary PCI plus stent implantation is indicated for treatment of acute coronary syndrome. Technically, due to the difference in lumen diameter between vessel portions and stent size in some coronary arteries, post-expansion of the stent is usually necessary to match proximal reference diameter and optimize stent apposition. Incomplete stent apposition has been associated with increased risk of in stent restenosis (ISR) and stent thrombosis (1) despite new stent technologies have largely reduced this risk (2-3). Although new antiplatelet drugs showed a more rapid onset of action and a stronger effect (4-5), stent apposition remains an important risk factor for stent thrombosis. As stent post-dilatation is commonly performed, typically with large over-expansion in the setting of long tapering vessel segment. There is an increasing recognition that information with regard to the different stent model designs can have a critical impact on resultsFile | Dimensione | Formato | |
---|---|---|---|
Sucato - Stent oversize.pdf
Solo gestori archvio
Tipologia:
Post-print
Dimensione
395.67 kB
Formato
Adobe PDF
|
395.67 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.