This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459-2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such parameters is discussed, for both single- and three-phase balanced/unbalanced cases, taking into account both their behavior in different scenarios and their effectiveness when the measurement uncertainty is taken into account. The study is supported by some simulation results that have been obtained on an IEEE benchmark power system, which allows reproducing linear and nonlinear load conditions, balanced and unbalanced operating conditions, and the presence of capacitors for power factor correction.

Artale G., Caravello G., Cataliotti A., Cosentino V., Cara D.D., Guaiana S., et al. (2021). Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 70, 1-10 [10.1109/TIM.2020.3037949].

Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010

Artale G.;Caravello G.;Cataliotti A.;Cosentino V.
;
2021-01-01

Abstract

This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459-2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such parameters is discussed, for both single- and three-phase balanced/unbalanced cases, taking into account both their behavior in different scenarios and their effectiveness when the measurement uncertainty is taken into account. The study is supported by some simulation results that have been obtained on an IEEE benchmark power system, which allows reproducing linear and nonlinear load conditions, balanced and unbalanced operating conditions, and the presence of capacitors for power factor correction.
2021
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Artale G., Caravello G., Cataliotti A., Cosentino V., Cara D.D., Guaiana S., et al. (2021). Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 70, 1-10 [10.1109/TIM.2020.3037949].
File in questo prodotto:
File Dimensione Formato  
TIM_2021_Measurement of simplified single- and three-phase parameters_.pdf

accesso aperto

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale
Dimensione 2.45 MB
Formato Adobe PDF
2.45 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/469224
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 13
social impact