A simple analytical model, including local effects due to buckling and shear to moment interaction, was developed to pre-dict the load-carrying capacity of CHS tubes under flexure and shear. A finite-element analysis with ABAQUS Code was also conducted for validation of the proposed model. By properly modeling the imperfection effects due to the ovalization of steel tube, a good correlation of the structural response and failure mode was also achieved, and a good correlation with the analytical model was also achieved. Numerical and analytical results were compared with experimental results recently obtained by the author with good agreement. Experimental tests refer to full-scale static test to failure were conducted on 6 m length of steel pipe constituting a segment of a telescopic wind tower with a 60-kW wind turbine. The diameter of the circular cross-section of steel pipes was 900 mm and the nominal thickness 10 mm. Steel grade was S355 J2, according to Eurocode 3. Although local buckling caused slight strength degradation, the reduction due to shear to moment interaction was very significant, while the recorded response showed a good amount of post-buckling ductility although the ovalization of cross-sections.
Giuseppe Campione, Francesco Cannella, Maurizio Papia (2020). Structural Behavior of Telescopic Steel Pipe for a Full-Scale 60 kW Wind Turbine Tower. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 20(2), 668-676 [10.1007/s13296-020-00313-9].
Structural Behavior of Telescopic Steel Pipe for a Full-Scale 60 kW Wind Turbine Tower
Giuseppe Campione
;Francesco Cannella;Maurizio Papia
2020-04-01
Abstract
A simple analytical model, including local effects due to buckling and shear to moment interaction, was developed to pre-dict the load-carrying capacity of CHS tubes under flexure and shear. A finite-element analysis with ABAQUS Code was also conducted for validation of the proposed model. By properly modeling the imperfection effects due to the ovalization of steel tube, a good correlation of the structural response and failure mode was also achieved, and a good correlation with the analytical model was also achieved. Numerical and analytical results were compared with experimental results recently obtained by the author with good agreement. Experimental tests refer to full-scale static test to failure were conducted on 6 m length of steel pipe constituting a segment of a telescopic wind tower with a 60-kW wind turbine. The diameter of the circular cross-section of steel pipes was 900 mm and the nominal thickness 10 mm. Steel grade was S355 J2, according to Eurocode 3. Although local buckling caused slight strength degradation, the reduction due to shear to moment interaction was very significant, while the recorded response showed a good amount of post-buckling ductility although the ovalization of cross-sections.File | Dimensione | Formato | |
---|---|---|---|
s13296-020-00313-9.pdf
Solo gestori archvio
Descrizione: articolo completo
Tipologia:
Versione Editoriale
Dimensione
1.57 MB
Formato
Adobe PDF
|
1.57 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.