The paper presents the design activities and testing plan of a vertical target mock-up, developed within the pre-conceptual design phase for DEMO Work Package DIV-1 "Divertor Cassette Design and Integration" - EUROfusion Power Plant Physics & Technology (PPPT) program.Activities concerning the Divertor Outboard Vertical Target cooling mock-up are presented in term of CAD model, thermal-hydraulic numerical simulation, structural analysis, structural integrity verification and manufacturing procedure. Moreover, the mechanical dimensions of support systems for Plasma Facing Components (PFCs), manifold and diffuser have been analyzed in detail, in order to avoid structural fault during the test.Test procedures are discussed, taking into account design parameters, design code and facility performances. The CuCrZr alloy selected for the PFCs of EU DEMO divertor has been used also for the mock-up, while two options are still under evaluation for manifolds/diffuser, CuCrZr and stainless Steel 316 L(N)-IG, depending on the joining technology. Since the mock-up is mainly intended to verify hydraulic performances, it has been simplified by removing the W monoblocks from its PFCs.

Mazzone, G., You, J.H., Cerri, V., Coccorese, D., Garitta, S., Di Gironimo, G., et al. (2019). Structural verification and manufacturing procedures of the cooling system, for DEMO divertor target (OVT). FUSION ENGINEERING AND DESIGN, 146, 1610-1614 [10.1016/j.fusengdes.2019.02.139].

Structural verification and manufacturing procedures of the cooling system, for DEMO divertor target (OVT)

Garitta S.;Di Maio P. A.;Vallone E.;
2019-01-01

Abstract

The paper presents the design activities and testing plan of a vertical target mock-up, developed within the pre-conceptual design phase for DEMO Work Package DIV-1 "Divertor Cassette Design and Integration" - EUROfusion Power Plant Physics & Technology (PPPT) program.Activities concerning the Divertor Outboard Vertical Target cooling mock-up are presented in term of CAD model, thermal-hydraulic numerical simulation, structural analysis, structural integrity verification and manufacturing procedure. Moreover, the mechanical dimensions of support systems for Plasma Facing Components (PFCs), manifold and diffuser have been analyzed in detail, in order to avoid structural fault during the test.Test procedures are discussed, taking into account design parameters, design code and facility performances. The CuCrZr alloy selected for the PFCs of EU DEMO divertor has been used also for the mock-up, while two options are still under evaluation for manifolds/diffuser, CuCrZr and stainless Steel 316 L(N)-IG, depending on the joining technology. Since the mock-up is mainly intended to verify hydraulic performances, it has been simplified by removing the W monoblocks from its PFCs.
2019
Settore ING-IND/19 - Impianti Nucleari
Mazzone, G., You, J.H., Cerri, V., Coccorese, D., Garitta, S., Di Gironimo, G., et al. (2019). Structural verification and manufacturing procedures of the cooling system, for DEMO divertor target (OVT). FUSION ENGINEERING AND DESIGN, 146, 1610-1614 [10.1016/j.fusengdes.2019.02.139].
File in questo prodotto:
File Dimensione Formato  
RI-81.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 1.54 MB
Formato Adobe PDF
1.54 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
RI_-_81_-_Pre-print.pdf

accesso aperto

Tipologia: Pre-print
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/393652
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact