This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and the three-phase applications downstream or upstream the metering section. It is based on the simultaneous measurement of three non-active power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is based only on the separation of the fundamental components from the harmonic content of voltage and current, thus it does not require any spectral analysis of voltages and current. In the paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are presented and discussed, showing the effectiveness of the method both in the absence and in the presence of the measurement transducers.

Cataliotti, A., Cosentino, V. (2009). Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 58(5), 1436-1445 [10.1109/TIM.2009.2015180].

Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000

CATALIOTTI, Antonio;COSENTINO, Valentina
2009-01-01

Abstract

This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and the three-phase applications downstream or upstream the metering section. It is based on the simultaneous measurement of three non-active power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is based only on the separation of the fundamental components from the harmonic content of voltage and current, thus it does not require any spectral analysis of voltages and current. In the paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are presented and discussed, showing the effectiveness of the method both in the absence and in the presence of the measurement transducers.
2009
Settore ING-INF/07 - Misure Elettriche E Elettroniche
Cataliotti, A., Cosentino, V. (2009). Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 58(5), 1436-1445 [10.1109/TIM.2009.2015180].
File in questo prodotto:
File Dimensione Formato  
TIM_09_Disturbing load identification in power systems.pdf

Solo gestori archvio

Descrizione: Articolo
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/39070
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 22
social impact