This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEEE standard three-phase test power system used by other authors as a benchmark to test harmonic sources detection methods. The analysis is carried out considering also the presence of the measurement transducers.

Cataliotti, A., Cosentino, V. (2009). A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems. METROLOGY AND MEASUREMENT SYSTEMS, XVI(2), 209-218.

A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems

CATALIOTTI, Antonio;COSENTINO, Valentina
2009-01-01

Abstract

This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEEE standard three-phase test power system used by other authors as a benchmark to test harmonic sources detection methods. The analysis is carried out considering also the presence of the measurement transducers.
2009
Cataliotti, A., Cosentino, V. (2009). A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems. METROLOGY AND MEASUREMENT SYSTEMS, XVI(2), 209-218.
File in questo prodotto:
File Dimensione Formato  
M&MS_2009_M-0244.pdf

Solo gestori archvio

Descrizione: Articolo
Dimensione 203.02 kB
Formato Adobe PDF
203.02 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/39065
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 5
social impact