This paper presents an experimental testing of a pultruded glass fiber reinforced polymer (FRP) structure used for emergency applications continuing the discussion presented in a previous paper (part 1) where the study of the characteristics of material and elements are presented. First, the design of the composite structure and components and the evaluation of the structural behavior by means of numerical and analytical approach according to current regulatory codes are described. In this frame, the global and local response was observed according to load paths deriving from the design loads at limit states. Then, the experimental test on a full-scale 2D model is presented at different load configurations up to the failure of the composite structure, comparing the experimental results with the load capacity predicted by the numerical model. The results indicate that the high performances of the structure provide a very good capacity in view of facing service loads and also in extreme conditions. Moreover, it was observed that the actual capacity obtained by the experimental test is much higher compared to the bearing capacity provided by the design according to current technical codes.

Cavaleri L., Di Paola M., Ferrotto M.F., Valenza A. (2019). Structural performances of pultruded GFRP emergency structures – Part 2: Full-scale experimental testing. COMPOSITE STRUCTURES, 214, 304-315 [10.1016/j.compstruct.2019.02.008].

Structural performances of pultruded GFRP emergency structures – Part 2: Full-scale experimental testing

Cavaleri L.
Membro del Collaboration Group
;
Di Paola M.
Membro del Collaboration Group
;
Ferrotto M. F.
Membro del Collaboration Group
;
Valenza A.
Membro del Collaboration Group
2019-01-01

Abstract

This paper presents an experimental testing of a pultruded glass fiber reinforced polymer (FRP) structure used for emergency applications continuing the discussion presented in a previous paper (part 1) where the study of the characteristics of material and elements are presented. First, the design of the composite structure and components and the evaluation of the structural behavior by means of numerical and analytical approach according to current regulatory codes are described. In this frame, the global and local response was observed according to load paths deriving from the design loads at limit states. Then, the experimental test on a full-scale 2D model is presented at different load configurations up to the failure of the composite structure, comparing the experimental results with the load capacity predicted by the numerical model. The results indicate that the high performances of the structure provide a very good capacity in view of facing service loads and also in extreme conditions. Moreover, it was observed that the actual capacity obtained by the experimental test is much higher compared to the bearing capacity provided by the design according to current technical codes.
2019
Cavaleri L., Di Paola M., Ferrotto M.F., Valenza A. (2019). Structural performances of pultruded GFRP emergency structures – Part 2: Full-scale experimental testing. COMPOSITE STRUCTURES, 214, 304-315 [10.1016/j.compstruct.2019.02.008].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0263822318345124-main.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/387690
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact