The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after the second disinfection, carried out 6 hours after the first one (T3). Impressions which were not disinfected served as controls. When both impression materials were disinfected with SP, significant differences were detected among all measurements (P < 0.0001), with the exception of T2 vs T3 (P > 0.05). On the other hand, when MD was used, significant differences were found when T0 measurement was compared to T1, T2 and T3 measurements (P = 0.0043 for PE, and P = 0.0014 for PVS). The dimensional change of all material/disinfectant combinations was always ≤0.5%. Therefore, the effects of immersion disinfection on the dimension of elastomers in SP or MD are not clinically relevant
Melilli, D., Rallo, A., Cassaro, A., Pizzo, G. (2008). The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials. JOURNAL OF ORAL SCIENCE, 50(4), 441-446.
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
MELILLI, Dario;RALLO, Antonio;CASSARO, Angelo;PIZZO, Giuseppe
2008-01-01
Abstract
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after the second disinfection, carried out 6 hours after the first one (T3). Impressions which were not disinfected served as controls. When both impression materials were disinfected with SP, significant differences were detected among all measurements (P < 0.0001), with the exception of T2 vs T3 (P > 0.05). On the other hand, when MD was used, significant differences were found when T0 measurement was compared to T1, T2 and T3 measurements (P = 0.0043 for PE, and P = 0.0014 for PVS). The dimensional change of all material/disinfectant combinations was always ≤0.5%. Therefore, the effects of immersion disinfection on the dimension of elastomers in SP or MD are not clinically relevantFile | Dimensione | Formato | |
---|---|---|---|
J Oral Sci 2008.pdf
Solo gestori archvio
Descrizione: Articolo principale
Dimensione
209.7 kB
Formato
Adobe PDF
|
209.7 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.