OBJECTIVE To retrospectively evaluate the clinical outcomes of 20 patients diagnosed with a nonpalpable or small testicular mass (2 cm) at 2 academic urological department. Testis-sparing surgery (TSS) is currently performed routinely for the management of nonpalpable testicular masses. High reliability of frozen section examination (FSE) and high-frequency ultrasound (US) and the adoption of microsurgical techniques improved safety and feasibility of this technique.METHODS From January 2004 to March 2011, 23 patients underwent microsurgical TSS. An inguinal approach was performed in 22 cases and a suprapubic incision in one bilateral case. All procedures were performed with an operating microscope, with warm ischemia in 21 cases and cold ischemia in 2 cases. Intraoperative US was performed before opening the albuginea. Mean operative time was 89 minutes.RESULTS After mass excision, FSE was performed; only 2 seminomatous tumors were identified, and the remaining masses were benign lesions. After a mean follow-up >12 months, all patients are free of disease; no hypogonadism developed.CONCLUSIONS TSS performed using an operating microscope allowed the preservation of testes for 21 patients diagnosed with small testicular and/or nonpalpable mass (<2 cm), without evidence of disease recurrence or de novo onset. This approach could be mandatory in the treatment of bilateral tumors or in solitary testis. Maintaining fertility is not the main goal of TSS because a great number of patients affected by testicular tumors are already infertile. Esthetic outcomes and sparing hormonal function are the main reasons for TSS. UROLOGY 79: 858-862, 2012. (C) 2012 Elsevier Inc.

De Stefani, S., Isgrò, G., Varca, V., Pecchi, A., Bianchi, G., Carmignani, G., et al. (2012). Microsurgical testis-sparing surgery in small testicular masses: seven years retrospective management and results. UROLOGY, 79(4), 858-862 [10.1016/j.urology.2011.12.039].

Microsurgical testis-sparing surgery in small testicular masses: seven years retrospective management and results

Simonato, Alchiede
Supervision
2012-01-01

Abstract

OBJECTIVE To retrospectively evaluate the clinical outcomes of 20 patients diagnosed with a nonpalpable or small testicular mass (2 cm) at 2 academic urological department. Testis-sparing surgery (TSS) is currently performed routinely for the management of nonpalpable testicular masses. High reliability of frozen section examination (FSE) and high-frequency ultrasound (US) and the adoption of microsurgical techniques improved safety and feasibility of this technique.METHODS From January 2004 to March 2011, 23 patients underwent microsurgical TSS. An inguinal approach was performed in 22 cases and a suprapubic incision in one bilateral case. All procedures were performed with an operating microscope, with warm ischemia in 21 cases and cold ischemia in 2 cases. Intraoperative US was performed before opening the albuginea. Mean operative time was 89 minutes.RESULTS After mass excision, FSE was performed; only 2 seminomatous tumors were identified, and the remaining masses were benign lesions. After a mean follow-up >12 months, all patients are free of disease; no hypogonadism developed.CONCLUSIONS TSS performed using an operating microscope allowed the preservation of testes for 21 patients diagnosed with small testicular and/or nonpalpable mass (<2 cm), without evidence of disease recurrence or de novo onset. This approach could be mandatory in the treatment of bilateral tumors or in solitary testis. Maintaining fertility is not the main goal of TSS because a great number of patients affected by testicular tumors are already infertile. Esthetic outcomes and sparing hormonal function are the main reasons for TSS. UROLOGY 79: 858-862, 2012. (C) 2012 Elsevier Inc.
2012
De Stefani, S., Isgrò, G., Varca, V., Pecchi, A., Bianchi, G., Carmignani, G., et al. (2012). Microsurgical testis-sparing surgery in small testicular masses: seven years retrospective management and results. UROLOGY, 79(4), 858-862 [10.1016/j.urology.2011.12.039].
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0090429511028160-main.pdf

Solo gestori archvio

Dimensione 864.37 kB
Formato Adobe PDF
864.37 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/356114
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 43
social impact