The structures of two samples of gold nanoclusters supported on silica were studied by X-ray powder diffraction (XRD) and X-ray absorption spectroscopy. The data relative to both techniques were analysed by an approach involving simulation based on structural models and fitting. The XRD model concerned a distorted f.c.c. (face-centred cubic) arrangement, with microstrains and parallel stacking faults in approximately spherical particles; as an alternative possibility, a linear combination of ordered f.c.c. and noncrystalline (decahedral and icosahedral) particles was also taken into account. Both approaches gave calculated patterns closely resembling the experimental data. X-ray absorption spectra were fitted on the basis of f.c.c. and noncrystalline arrangements. The best results were obtained by the f.c.c. motif, while a simulation consisting in the superposition of f.c.c. and noncrystalline components in the relative amounts determined by XRD analysis gave a poor agreement with the experimental data. It was concluded that the good XRD fitting obtained by linear combination of lognormal size-distributed f.c.c. cuboctahedral, decahedral and icosahedral contributions was a result of the flexibility of the basis set of functions, but that the complementary analysis of X-ray absorption data did not confirm the presence of a noteworthy fraction of noncrystalline particles.

Longo, A., Martorana, A. (2008). Distorted f.c.c. arrangement of gold nanoclusters: a model of spherical particles with microstrains and stacking faults. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 41, 446-455 [10.1107/S0021889808004846].

Distorted f.c.c. arrangement of gold nanoclusters: a model of spherical particles with microstrains and stacking faults

MARTORANA, Antonino
2008-01-01

Abstract

The structures of two samples of gold nanoclusters supported on silica were studied by X-ray powder diffraction (XRD) and X-ray absorption spectroscopy. The data relative to both techniques were analysed by an approach involving simulation based on structural models and fitting. The XRD model concerned a distorted f.c.c. (face-centred cubic) arrangement, with microstrains and parallel stacking faults in approximately spherical particles; as an alternative possibility, a linear combination of ordered f.c.c. and noncrystalline (decahedral and icosahedral) particles was also taken into account. Both approaches gave calculated patterns closely resembling the experimental data. X-ray absorption spectra were fitted on the basis of f.c.c. and noncrystalline arrangements. The best results were obtained by the f.c.c. motif, while a simulation consisting in the superposition of f.c.c. and noncrystalline components in the relative amounts determined by XRD analysis gave a poor agreement with the experimental data. It was concluded that the good XRD fitting obtained by linear combination of lognormal size-distributed f.c.c. cuboctahedral, decahedral and icosahedral contributions was a result of the flexibility of the basis set of functions, but that the complementary analysis of X-ray absorption data did not confirm the presence of a noteworthy fraction of noncrystalline particles.
2008
Settore CHIM/03 - Chimica Generale E Inorganica
Longo, A., Martorana, A. (2008). Distorted f.c.c. arrangement of gold nanoclusters: a model of spherical particles with microstrains and stacking faults. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 41, 446-455 [10.1107/S0021889808004846].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/35583
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 29
social impact