This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the contaminant was carried through the network to the point-of-use when the pipes become completely full and the distribution system was in steady state conditions, in the second, and that the concentrations was higher than in the first set of tests

Fontanazza, C.M., Notaro, V., Puleo, V., Nicolosi, P., Freni, G. (2015). Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis. PROCEDIA ENGINEERING, 119, 426-433 [10.1016/j.proeng.2015.08.904].

Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis

Fontanazza, Chiara M.
;
Notaro, Vincenza;Puleo, Valeria;Freni, Gabriele
2015-01-01

Abstract

This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the contaminant was carried through the network to the point-of-use when the pipes become completely full and the distribution system was in steady state conditions, in the second, and that the concentrations was higher than in the first set of tests
2015
Fontanazza, C.M., Notaro, V., Puleo, V., Nicolosi, P., Freni, G. (2015). Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis. PROCEDIA ENGINEERING, 119, 426-433 [10.1016/j.proeng.2015.08.904].
File in questo prodotto:
File Dimensione Formato  
16 - Fontanazza et al Procedia 2015 Contaminant intrusion.pdf

accesso aperto

Descrizione: Articolo principale
Dimensione 455.2 kB
Formato Adobe PDF
455.2 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/355232
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 44
social impact