A galvanic method to deposit chitosan coatings on stainless steel substrate is reported. Deposition of suitable coatings is desired to improve biocompatibility and corrosion resistance of metallic medical devices to be implanted in human body. In the present work, a thin hydrogel layer of chitosan was deposited on 304SS by a galvanic displacement reaction, which is advantageous first as it does not require external power supply. 304SS was immersed into an aqueous solution of chitosan/lactic acid and electrochemically coupled with magnesium acting as a sacrificial anode. SEM images showed the formation of a uniform layer of chitosan with a thickness controlled by deposition time. Corrosion tests in simulating body fluid showed that chitosan coatings shift the corrosion potential of 304 substrates toward nobler values. Finally, the cytotoxicity of the coating was investigated through cell viability assays with osteoblastic cell MC3T3-E1. The results revealed highly satisfying biocompatibility of the coating.

Blanda, G., Brucato, V., Carfì, F., Conoscenti, G., La Carrubba, V., Piazza, S., et al. (2019). Chitosan-Coating Deposition via Galvanic Coupling. ACS BIOMATERIALS SCIENCE & ENGINEERING, 5(4), 1715-1724 [10.1021/acsbiomaterials.8b01548].

Chitosan-Coating Deposition via Galvanic Coupling

Blanda, Giuseppe
Membro del Collaboration Group
;
Brucato, Valerio
Membro del Collaboration Group
;
Carfì, Francesco
Membro del Collaboration Group
;
Conoscenti, Gioacchino
Membro del Collaboration Group
;
La Carrubba, Vincenzo
Membro del Collaboration Group
;
Piazza, Salvatore
Membro del Collaboration Group
;
Sunseri, Carmelo
Membro del Collaboration Group
;
Inguanta, Rosalinda
Membro del Collaboration Group
2019-01-01

Abstract

A galvanic method to deposit chitosan coatings on stainless steel substrate is reported. Deposition of suitable coatings is desired to improve biocompatibility and corrosion resistance of metallic medical devices to be implanted in human body. In the present work, a thin hydrogel layer of chitosan was deposited on 304SS by a galvanic displacement reaction, which is advantageous first as it does not require external power supply. 304SS was immersed into an aqueous solution of chitosan/lactic acid and electrochemically coupled with magnesium acting as a sacrificial anode. SEM images showed the formation of a uniform layer of chitosan with a thickness controlled by deposition time. Corrosion tests in simulating body fluid showed that chitosan coatings shift the corrosion potential of 304 substrates toward nobler values. Finally, the cytotoxicity of the coating was investigated through cell viability assays with osteoblastic cell MC3T3-E1. The results revealed highly satisfying biocompatibility of the coating.
2019
Settore ING-IND/23 - Chimica Fisica Applicata
Settore ING-IND/24 - Principi Di Ingegneria Chimica
Settore ING-IND/34 - Bioingegneria Industriale
Blanda, G., Brucato, V., Carfì, F., Conoscenti, G., La Carrubba, V., Piazza, S., et al. (2019). Chitosan-Coating Deposition via Galvanic Coupling. ACS BIOMATERIALS SCIENCE & ENGINEERING, 5(4), 1715-1724 [10.1021/acsbiomaterials.8b01548].
File in questo prodotto:
File Dimensione Formato  
proof-MOD.pdf

Solo gestori archvio

Descrizione: profs dell'articolo
Tipologia: Post-print
Dimensione 5.37 MB
Formato Adobe PDF
5.37 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
blanda-et-al-2019-chitosan-coating-deposition-via-galvanic-coupling.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 5.4 MB
Formato Adobe PDF
5.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/352962
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 14
social impact