The closed-loop control of internal combustion engine spark timing may be accomplished by means of a combustion phase indicator i.e., a parameter derived from in-cylinder pressure analysis, whose variation is mainly referable to combustion phase shift and assumes a fixed reference value under optimal spark timing operation. The aim of the present work is a comparison between different combustion phase indicators, focusing on the performance attainable by a feedback spark timing control, which uses the indicator as pilot variable. An extensive experimental investigation has been carried out, verifying the relationship between indicators' optimal values and the main engine running parameters: engine speed, load, and mixture strength. Moreover assessment on the effect of the most common pressure measurement problems (which are mainly related to pressure referencing, sampling resolution, top dead center determination, and cycle-by-cycle variations) on the indicators' values and on the performance attainable by the spark timing control is included. The results of the comparison point out two indicators as the most suitable: the location of pressure peak and the location of maximum heat release rate. The latter, not available in literature, has been introduced by the author as an alternative to the 50% of mass fraction burned.

PIPITONE E (2008). A COMPARISON BETWEEN COMBUSTION PHASE INDICATORS FOR OPTIMAL SPARK TIMING. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER, 130(5), 052808-1-052808-11 [10.1115/1.2939012].

A COMPARISON BETWEEN COMBUSTION PHASE INDICATORS FOR OPTIMAL SPARK TIMING

PIPITONE, Emiliano
2008-01-01

Abstract

The closed-loop control of internal combustion engine spark timing may be accomplished by means of a combustion phase indicator i.e., a parameter derived from in-cylinder pressure analysis, whose variation is mainly referable to combustion phase shift and assumes a fixed reference value under optimal spark timing operation. The aim of the present work is a comparison between different combustion phase indicators, focusing on the performance attainable by a feedback spark timing control, which uses the indicator as pilot variable. An extensive experimental investigation has been carried out, verifying the relationship between indicators' optimal values and the main engine running parameters: engine speed, load, and mixture strength. Moreover assessment on the effect of the most common pressure measurement problems (which are mainly related to pressure referencing, sampling resolution, top dead center determination, and cycle-by-cycle variations) on the indicators' values and on the performance attainable by the spark timing control is included. The results of the comparison point out two indicators as the most suitable: the location of pressure peak and the location of maximum heat release rate. The latter, not available in literature, has been introduced by the author as an alternative to the 50% of mass fraction burned.
2008
Settore ING-IND/08 - Macchine A Fluido
PIPITONE E (2008). A COMPARISON BETWEEN COMBUSTION PHASE INDICATORS FOR OPTIMAL SPARK TIMING. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER, 130(5), 052808-1-052808-11 [10.1115/1.2939012].
File in questo prodotto:
File Dimensione Formato  
Combustion Phase Indicators - GTP-07-1186 .pdf

Solo gestori archvio

Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/34579
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 37
social impact