In this work a high frequency model of a photovoltaic (PV) plant is identified and implemented aiming to investigate the common mode (CM) currents circulating through the ground connections of the plant. From the identification of the impedance obtained by frequency response of photovoltaic module and by a suitable of the power conversion unit, an equivalent high frequency circuit representation has been developed. The lumped parameters circuit model is implemented in PSpice environment to obtain the CM leakage currents. Harmonics at frequencies multiple of the switching frequency and a strong resonance at about 12 MHz are detected.
Di Piazza, M., Viola, F., Vitale, G. (2018). Evaluation of ground currents in a PV system with high frequency modeling. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 8(3), 1770-1778.
Evaluation of ground currents in a PV system with high frequency modeling
Di Piazza, M. C.;Viola, F.
;Vitale, G.
2018-01-01
Abstract
In this work a high frequency model of a photovoltaic (PV) plant is identified and implemented aiming to investigate the common mode (CM) currents circulating through the ground connections of the plant. From the identification of the impedance obtained by frequency response of photovoltaic module and by a suitable of the power conversion unit, an equivalent high frequency circuit representation has been developed. The lumped parameters circuit model is implemented in PSpice environment to obtain the CM leakage currents. Harmonics at frequencies multiple of the switching frequency and a strong resonance at about 12 MHz are detected.File | Dimensione | Formato | |
---|---|---|---|
7890-29185-1-PB.pdf
accesso aperto
Dimensione
943.17 kB
Formato
Adobe PDF
|
943.17 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.