In this research paper, we report a method able to detect perfluorinated compound at pg·L-1levels in superficial and underground water samples. An online solid phase extraction HPLC-MS/MS method was developed for the analysis of 12 perfluoroalkyl acids (PFASs). The method is based on injection of 5000 μL of water sample in SPE online WAX column followed by chromatography separation and mass spectrometry determination. SPE online elution was performed by water + 0.05% NH4OH and methanol + 0.05% NH4OH, while separation of target compounds was achieved within 10 min by Gemini chromatographic column operating from 1 to 12 pH range and using a mixture of water-methanol + 0.05% NH4OH. Sub ng·L-1method detection limits (from 0.2 to 5 ng·L-1), linearity (from 0.2 to 250 ng·L-1), accuracy (from 80 to 120%), and precision (RSD less than 15% at LOQs levels) were achieved. The method is capable of measuring PFAS at trace levels, but above all it can reach the limit of 200 pg·L-1required by European regulation for PFOS determination in surface and underground waters. The method was validated for quantitative analysis of PFASs in real water samples.
Barreca, S., Busetto, M., Vitelli, M., Colzani, L., Clerici, L., Dellavedova, P. (2018). Online Solid-Phase Extraction LC-MS/MS: A Rapid and Valid Method for the Determination of Perfluorinated Compounds at Sub ng·L-1Level in Natural Water. JOURNAL OF CHEMISTRY, 2018, 1-9 [10.1155/2018/3780825].
Online Solid-Phase Extraction LC-MS/MS: A Rapid and Valid Method for the Determination of Perfluorinated Compounds at Sub ng·L-1Level in Natural Water
Barreca, Salvatore
;
2018-01-01
Abstract
In this research paper, we report a method able to detect perfluorinated compound at pg·L-1levels in superficial and underground water samples. An online solid phase extraction HPLC-MS/MS method was developed for the analysis of 12 perfluoroalkyl acids (PFASs). The method is based on injection of 5000 μL of water sample in SPE online WAX column followed by chromatography separation and mass spectrometry determination. SPE online elution was performed by water + 0.05% NH4OH and methanol + 0.05% NH4OH, while separation of target compounds was achieved within 10 min by Gemini chromatographic column operating from 1 to 12 pH range and using a mixture of water-methanol + 0.05% NH4OH. Sub ng·L-1method detection limits (from 0.2 to 5 ng·L-1), linearity (from 0.2 to 250 ng·L-1), accuracy (from 80 to 120%), and precision (RSD less than 15% at LOQs levels) were achieved. The method is capable of measuring PFAS at trace levels, but above all it can reach the limit of 200 pg·L-1required by European regulation for PFOS determination in surface and underground waters. The method was validated for quantitative analysis of PFASs in real water samples.File | Dimensione | Formato | |
---|---|---|---|
PFAS.pdf
accesso aperto
Dimensione
1.82 MB
Formato
Adobe PDF
|
1.82 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.