In the last decades, with the fast improvement of electronics, the field of sensors is highly expanding. The basic idea of sensors is to detect something and then trigger a corresponding action. This simple, but very important, concept can be used in different fields: from chemical industries to farms, from the environmental monitoring [1] to a point of care analysis [2]. Currently, talking about sensing of chemical species, different techniques are used, such as Atomic Absorption Spectroscopy (AAS), Graphite Furnace Atomic Absorption Spectroscopy (GFAAS), Inductively Coupled Plasma Mass Spectroscopy (ICP-MS), IR spectroscopy, redox titration and so on. Despite they are highly efficient in terms of sensitivity, selectivity, Limit Of Detection (LOD) and accuracy they have different drawbacks: first of all, are extremely expensive for both equipment and operational costs, require highly skilled personnel, are time consuming and, above all, are just laboratory techniques so can’t be used as in situ and real time analysis. Taking advantage of brilliant attributes, such as, portable, simple to develop, the use-friendliness, economical, miniaturized dimensions, in recent years, many researchers are working on electrochemical sensors based on nanostructures and/or nanomaterials. Electrochemistry provide a wide range of applications for the detection of chemical targets depending on the technique that is used. In this work, ordered array of Pd and Cu nanowires was obtained through a displacement deposition reaction in a commercial polycarbonate membrane and used as an electrochemical sensor of hydrogen peroxide. Detection of hydrogen peroxide is very important in several fields because, owing to its oxidizing and reducing properties, this compound is widely used for treatment of waste water, paper and contaminated soil and also in medical applications ‘cause his concentration can be related to the glucose concentration in the blood. Hydrogen peroxide detection, trough chronoamperometry, occurs due to a redox reaction that happen at the electrode/electrolyte interface. Consequently, the higher is the surface area the better will be the features of the sensor. This is the reason why we choose to use a nanostructured electrode. The nanostructured electrodes were obtained by a two steps methods that permit to obtain very stable nano-electrodes of Pd and Cu with a very high surface area. We carried out selectivity tests against four different species, accuracy tests obtaining very high selectivity with a good accuracy and a low LOD in a very wide linear range (Figure 1 and Table 1).

Patella, B., Piazza, S., Sunseri, C., Inguanta, R. (2018). ELECTROCHEMICAL H2O2 SENSORS BASED ON Pd and Cu NANOSTRUCUTERS. In CNS 2018 4° Convegno Nazionale Sensori.

ELECTROCHEMICAL H2O2 SENSORS BASED ON Pd and Cu NANOSTRUCUTERS

Patella, Bernardo
Membro del Collaboration Group
;
Piazza, Salvatore;Sunseri, Carmelo
Membro del Collaboration Group
;
Inguanta, Rosalinda
Membro del Collaboration Group
2018-01-01

Abstract

In the last decades, with the fast improvement of electronics, the field of sensors is highly expanding. The basic idea of sensors is to detect something and then trigger a corresponding action. This simple, but very important, concept can be used in different fields: from chemical industries to farms, from the environmental monitoring [1] to a point of care analysis [2]. Currently, talking about sensing of chemical species, different techniques are used, such as Atomic Absorption Spectroscopy (AAS), Graphite Furnace Atomic Absorption Spectroscopy (GFAAS), Inductively Coupled Plasma Mass Spectroscopy (ICP-MS), IR spectroscopy, redox titration and so on. Despite they are highly efficient in terms of sensitivity, selectivity, Limit Of Detection (LOD) and accuracy they have different drawbacks: first of all, are extremely expensive for both equipment and operational costs, require highly skilled personnel, are time consuming and, above all, are just laboratory techniques so can’t be used as in situ and real time analysis. Taking advantage of brilliant attributes, such as, portable, simple to develop, the use-friendliness, economical, miniaturized dimensions, in recent years, many researchers are working on electrochemical sensors based on nanostructures and/or nanomaterials. Electrochemistry provide a wide range of applications for the detection of chemical targets depending on the technique that is used. In this work, ordered array of Pd and Cu nanowires was obtained through a displacement deposition reaction in a commercial polycarbonate membrane and used as an electrochemical sensor of hydrogen peroxide. Detection of hydrogen peroxide is very important in several fields because, owing to its oxidizing and reducing properties, this compound is widely used for treatment of waste water, paper and contaminated soil and also in medical applications ‘cause his concentration can be related to the glucose concentration in the blood. Hydrogen peroxide detection, trough chronoamperometry, occurs due to a redox reaction that happen at the electrode/electrolyte interface. Consequently, the higher is the surface area the better will be the features of the sensor. This is the reason why we choose to use a nanostructured electrode. The nanostructured electrodes were obtained by a two steps methods that permit to obtain very stable nano-electrodes of Pd and Cu with a very high surface area. We carried out selectivity tests against four different species, accuracy tests obtaining very high selectivity with a good accuracy and a low LOD in a very wide linear range (Figure 1 and Table 1).
2018
Patella, B., Piazza, S., Sunseri, C., Inguanta, R. (2018). ELECTROCHEMICAL H2O2 SENSORS BASED ON Pd and Cu NANOSTRUCUTERS. In CNS 2018 4° Convegno Nazionale Sensori.
File in questo prodotto:
File Dimensione Formato  
CNS_2018_paper_7.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 228.55 kB
Formato Adobe PDF
228.55 kB Adobe PDF Visualizza/Apri
Booklet_Programma_CNS2018.pdf

Solo gestori archvio

Tipologia: Altro materiale (es. dati della ricerca)
Dimensione 1.48 MB
Formato Adobe PDF
1.48 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/297664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact