The paper presents a life cycle assessment of a kenaf-fibre insulation board following the international standards of the ISO 14040 series. Each life-cycle step has been checked, from kenaf production and board manufacture by an Italian firm, to use and disposal. The aim is to assess the board eco-profile and to compare, on the basis of a life-cycle approach, the energy and environmental benefits and drawbacks related to its employment into a typical residential dwelling. A comparison among various insulating materials has been carried out. The study focuses also on processes and input materials which cause the main environmental impacts of the product, and points out critical issues and the life-cycle steps with the highest improvement potentials

F ARDENTE, M BECCALI, CELLURA M, M MISTRETTA (2008). Building Energy Performance: A LCA Case Study of kenaf-fibres insulation board. ENERGY AND BUILDINGS, 40 Issue 1, 1-10 [10.1016/j.enbuild.2006.12.009].

Building Energy Performance: A LCA Case Study of kenaf-fibres insulation board

ARDENTE, Fulvio;BECCALI, Marco;CELLURA, Maurizio;
2008-01-01

Abstract

The paper presents a life cycle assessment of a kenaf-fibre insulation board following the international standards of the ISO 14040 series. Each life-cycle step has been checked, from kenaf production and board manufacture by an Italian firm, to use and disposal. The aim is to assess the board eco-profile and to compare, on the basis of a life-cycle approach, the energy and environmental benefits and drawbacks related to its employment into a typical residential dwelling. A comparison among various insulating materials has been carried out. The study focuses also on processes and input materials which cause the main environmental impacts of the product, and points out critical issues and the life-cycle steps with the highest improvement potentials
2008
F ARDENTE, M BECCALI, CELLURA M, M MISTRETTA (2008). Building Energy Performance: A LCA Case Study of kenaf-fibres insulation board. ENERGY AND BUILDINGS, 40 Issue 1, 1-10 [10.1016/j.enbuild.2006.12.009].
File in questo prodotto:
File Dimensione Formato  
Building Energy Performance A LCA Case Study of kenaf fibres insulation board.pdf

Solo gestori archvio

Dimensione 515.62 kB
Formato Adobe PDF
515.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/28024
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 236
  • ???jsp.display-item.citation.isi??? 183
social impact