Many different analysis techniques have been developed and applied to EEG recordings that allow one to investigate how different brain areas interact. One particular class of methods, based on the linear parametric representation of multiple interacting time series, is widely used to study causal connectivity in the brain. However, the results obtained by these methods should be interpreted with great care. The goal of this paper is to show, both theoretically and using simulations, that results obtained by applying causal connectivity measures on the sensor (scalp) time series do not allow interpretation in terms of interacting brain sources. This is because (1) the channel locations cannot be seen as an approximation of a sourceâ s anatomical location and (2) spurious connectivity can occur between sensors. Although many measures of causal connectivity derived from EEG sensor time series are affected by the latter, here we will focus on the well-known time domain index of Granger causality (GC) and on the frequency domain directed transfer function (DTF). Using the state-space framework and designing two simulation studies we show that mixing effects caused by volume conduction can lead to spurious connections, detected either by time domain GC or by DTF. Therefore, GC/DTF causal connectivity measures should be computed at the source level, or derived within analysis frameworks that model the effects of volume conduction. Since mixing effects can also occur in the source space, it is advised to combine source space analysis with connectivity measures that are robust to mixing.

van de Steen, F., Faes, L., Karahan, E., Songsiri, J., Valdes-Sosa, P.A., Marinazzo, D. (2019). Critical Comments on EEG Sensor Space Dynamical Connectivity Analysis. BRAIN TOPOGRAPHY, 32, 643-654 [10.1007/s10548-016-0538-7].

Critical Comments on EEG Sensor Space Dynamical Connectivity Analysis

Faes, Luca;
2019-01-01

Abstract

Many different analysis techniques have been developed and applied to EEG recordings that allow one to investigate how different brain areas interact. One particular class of methods, based on the linear parametric representation of multiple interacting time series, is widely used to study causal connectivity in the brain. However, the results obtained by these methods should be interpreted with great care. The goal of this paper is to show, both theoretically and using simulations, that results obtained by applying causal connectivity measures on the sensor (scalp) time series do not allow interpretation in terms of interacting brain sources. This is because (1) the channel locations cannot be seen as an approximation of a sourceâ s anatomical location and (2) spurious connectivity can occur between sensors. Although many measures of causal connectivity derived from EEG sensor time series are affected by the latter, here we will focus on the well-known time domain index of Granger causality (GC) and on the frequency domain directed transfer function (DTF). Using the state-space framework and designing two simulation studies we show that mixing effects caused by volume conduction can lead to spurious connections, detected either by time domain GC or by DTF. Therefore, GC/DTF causal connectivity measures should be computed at the source level, or derived within analysis frameworks that model the effects of volume conduction. Since mixing effects can also occur in the source space, it is advised to combine source space analysis with connectivity measures that are robust to mixing.
2019
Settore ING-INF/06 - Bioingegneria Elettronica E Informatica
van de Steen, F., Faes, L., Karahan, E., Songsiri, J., Valdes-Sosa, P.A., Marinazzo, D. (2019). Critical Comments on EEG Sensor Space Dynamical Connectivity Analysis. BRAIN TOPOGRAPHY, 32, 643-654 [10.1007/s10548-016-0538-7].
File in questo prodotto:
File Dimensione Formato  
73-VandeSteen_BrainTopography2016.pdf

Solo gestori archvio

Descrizione: ahead of print
Tipologia: Versione Editoriale
Dimensione 963.33 kB
Formato Adobe PDF
963.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
VanDeSteen2019_Article_CriticalCommentsOnEEGSensorSpa.pdf

Solo gestori archvio

Tipologia: Versione Editoriale
Dimensione 924.81 kB
Formato Adobe PDF
924.81 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
postprint_btop.pdf

accesso aperto

Tipologia: Post-print
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/276424
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 87
social impact