Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. A comparative evaluation study has been performed considering the two different options under consideration for the divertor cassette body coolant, namely subcooled pressurized water and helium. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. CFD analyses have been carried out for the considered options of cassette body cooling circuit under nominal steady state conditions and the pertaining thermal-hydraulic performances have been assessed in terms of overall coolant thermal rise, coolant total pressure drop, flow velocity and pumping power, to check whether they comply with the corresponding limits. Results obtained are reported and critically discussed

Di Maio, P., Garitta, S., You, J., Mazzone, G., Vallone, E. (2017). Analysis of steady state thermal-hydraulic behaviour of the DEMO divertor cassette body cooling circuit. FUSION ENGINEERING AND DESIGN, 124, 437-441 [10.1016/j.fusengdes.2017.02.012].

Analysis of steady state thermal-hydraulic behaviour of the DEMO divertor cassette body cooling circuit

Di Maio, P. A.;Garitta, S.;Vallone, E.
2017-01-01

Abstract

Within the framework of the Work Package DIV 1 – “Divertor Cassette Design and Integration” of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. A comparative evaluation study has been performed considering the two different options under consideration for the divertor cassette body coolant, namely subcooled pressurized water and helium. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. CFD analyses have been carried out for the considered options of cassette body cooling circuit under nominal steady state conditions and the pertaining thermal-hydraulic performances have been assessed in terms of overall coolant thermal rise, coolant total pressure drop, flow velocity and pumping power, to check whether they comply with the corresponding limits. Results obtained are reported and critically discussed
2017
Settore ING-IND/19 - Impianti Nucleari
Di Maio, P., Garitta, S., You, J., Mazzone, G., Vallone, E. (2017). Analysis of steady state thermal-hydraulic behaviour of the DEMO divertor cassette body cooling circuit. FUSION ENGINEERING AND DESIGN, 124, 437-441 [10.1016/j.fusengdes.2017.02.012].
File in questo prodotto:
File Dimensione Formato  
RI-55.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 1.82 MB
Formato Adobe PDF
1.82 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/274817
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact