Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 Ã 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endovascular mean (3 stent-graft implantations and 3 coil embolization). The remaining 2 cases were managed surgically (one of these after failed coil embolization). In conclusion, the use of covered stent graft was effective to treat a DFAP localized in the medium DFA. This tool allowed maintaining the native DFA patency and the preservation of its main branches.
Pecoraro, F., Dinoto, E., Bracale, U., Badalamenti, G., Farina, A., Bajardi, G. (2017). Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review. ANNALS OF VASCULAR SURGERY, 42, 303.e5-303.e9 [10.1016/j.avsg.2016.11.026].
Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review
Pecoraro, Felice
;Dinoto, Ettore;Bajardi, Guido
2017-01-01
Abstract
Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 Ã 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endovascular mean (3 stent-graft implantations and 3 coil embolization). The remaining 2 cases were managed surgically (one of these after failed coil embolization). In conclusion, the use of covered stent graft was effective to treat a DFAP localized in the medium DFA. This tool allowed maintaining the native DFA patency and the preservation of its main branches.File | Dimensione | Formato | |
---|---|---|---|
83_2017_DeepFemAN_AnnVascSurg.pdf
Solo gestori archvio
Dimensione
678.55 kB
Formato
Adobe PDF
|
678.55 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.