This article describes Electron Spin Resonance (ESR) response measurements of Kodak BioMax alanine films exposed to low-energy X-rays from a Cu-target tube operating at 20 kV. Commercial alanine detectors were used to ensure maximum reproducibility of the results, while the choice of a film was due the low penetration of the soft X-rays. X-ray energy spectra and fluences were determined with an innovative digital semiconductor detector system. These data were used to quantify the irradiation of the alanine films in terms of absorbed dose to water. The alanine films were found to present a stable response, highly linear with dose. To our knowledge, these data have not been previously reported and they may be extremely relevant, e.g., when mapping the high-gradient treatment fields used in microbeam radiation therapy (MRT) with synchrotron radiation.

Marrale, M., Abbene, L., d'Errico, F., Gallo, S., Longo, A., Panzeca, S., et al. (2017). Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons. RADIATION MEASUREMENTS, 106, 200-204 [10.1016/j.radmeas.2017.03.009].

Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons

Marrale, M;Abbene, L;d'Errico, F;Principato, F
2017-01-01

Abstract

This article describes Electron Spin Resonance (ESR) response measurements of Kodak BioMax alanine films exposed to low-energy X-rays from a Cu-target tube operating at 20 kV. Commercial alanine detectors were used to ensure maximum reproducibility of the results, while the choice of a film was due the low penetration of the soft X-rays. X-ray energy spectra and fluences were determined with an innovative digital semiconductor detector system. These data were used to quantify the irradiation of the alanine films in terms of absorbed dose to water. The alanine films were found to present a stable response, highly linear with dose. To our knowledge, these data have not been previously reported and they may be extremely relevant, e.g., when mapping the high-gradient treatment fields used in microbeam radiation therapy (MRT) with synchrotron radiation.
2017
Marrale, M., Abbene, L., d'Errico, F., Gallo, S., Longo, A., Panzeca, S., et al. (2017). Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons. RADIATION MEASUREMENTS, 106, 200-204 [10.1016/j.radmeas.2017.03.009].
File in questo prodotto:
File Dimensione Formato  
RM_2017_Marrale_Lax.pdf

Solo gestori archvio

Descrizione: Ahead of print
Tipologia: Versione Editoriale
Dimensione 647.42 kB
Formato Adobe PDF
647.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Marrale et al 2017.pdf

Solo gestori archvio

Descrizione: Articolo
Tipologia: Versione Editoriale
Dimensione 584.18 kB
Formato Adobe PDF
584.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/225740
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact