Cosmic plasma conditions created in an electron beam ion trap (EBIT) make it possible to simulate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources. We used a microcalorimeter for such laboratory astrophysics studies because it has a resolving power ≈1000, quantum efficiency approaching 100%, and a bandwidth that spans the X-ray energies from 0.2 keV to 10 keV. Our microcalorimeter, coupled with an X-ray optic to increase the effective solid angle, provides a significant new capability for laboratory astrophysics measurements. Broadband spectra obtained from the National Institute of Standards and Technology EBIT with an energy resolution approaching that of a Bragg crystal spectrometer are presented for nitrogen, oxygen, neon, argon, and krypton in various stages of ionization. We have compared the measured line intensities to theoretical predictions for an EBIT plasma.

Silver, E., Schnopper, H., Bandler, S., Brickhouse, N., Murray, S., Barbera, M., et al. (2000). Laboratory astrophysics survey of key x-ray diagnostic lines using a microcalorimeter on an electron beam ion trap. THE ASTROPHYSICAL JOURNAL, 541(1 PART 1), 495-500 [10.1086/309420].

Laboratory astrophysics survey of key x-ray diagnostic lines using a microcalorimeter on an electron beam ion trap

BARBERA, Marco;
2000-01-01

Abstract

Cosmic plasma conditions created in an electron beam ion trap (EBIT) make it possible to simulate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources. We used a microcalorimeter for such laboratory astrophysics studies because it has a resolving power ≈1000, quantum efficiency approaching 100%, and a bandwidth that spans the X-ray energies from 0.2 keV to 10 keV. Our microcalorimeter, coupled with an X-ray optic to increase the effective solid angle, provides a significant new capability for laboratory astrophysics measurements. Broadband spectra obtained from the National Institute of Standards and Technology EBIT with an energy resolution approaching that of a Bragg crystal spectrometer are presented for nitrogen, oxygen, neon, argon, and krypton in various stages of ionization. We have compared the measured line intensities to theoretical predictions for an EBIT plasma.
2000
Silver, E., Schnopper, H., Bandler, S., Brickhouse, N., Murray, S., Barbera, M., et al. (2000). Laboratory astrophysics survey of key x-ray diagnostic lines using a microcalorimeter on an electron beam ion trap. THE ASTROPHYSICAL JOURNAL, 541(1 PART 1), 495-500 [10.1086/309420].
File in questo prodotto:
File Dimensione Formato  
Silver_2000_ApJ_541_495.pdf

Solo gestori archvio

Dimensione 579.21 kB
Formato Adobe PDF
579.21 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/215276
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 44
social impact