Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into three groups: normal, moderate and severe oversizing; depending on the ratio between the prosthesis area and the annulus area indexed and measured on MSCT. Main endpoint was mid-term mortality and secondary endpoints were the Valve Academic Research Consortium (VARC-2) endpoints. Results Two hundred and sixty eight patients had a MSCT and underwent TAVI procedure, with mainly Corevalve®. While all-cause and cardiovascular mortality rates were similar in all groups, post-procedural new pacemaker (PM) implantation rate was significantly higher in the severe oversizing group (P = 0.03), while we observed more in-hospital congestive heart-failure (P = 0.02) in the normal sizing group. There was a trend toward more moderate to severe aortic regurgitation (AR) in the normal sizing group (P = 0.07). Conclusions Despite a higher rate of PM implantation, oversizing based on this ratio reduces aortic leak with lower rates of post-procedural complications and a similar mid-term survival.

Derby, N., Sudre, A., Elquodeimat, I., Delhaye, C., Schurtzy, G., Bical, A., et al. (2016). Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures. JOURNAL OF GERIATRIC CARDIOLOGY, 13, 483-488 [10.11909/j.issn.1671-5411.2016.06.004].

Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures

FATTOUCH, Khalil;
2016-06-28

Abstract

Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into three groups: normal, moderate and severe oversizing; depending on the ratio between the prosthesis area and the annulus area indexed and measured on MSCT. Main endpoint was mid-term mortality and secondary endpoints were the Valve Academic Research Consortium (VARC-2) endpoints. Results Two hundred and sixty eight patients had a MSCT and underwent TAVI procedure, with mainly Corevalve®. While all-cause and cardiovascular mortality rates were similar in all groups, post-procedural new pacemaker (PM) implantation rate was significantly higher in the severe oversizing group (P = 0.03), while we observed more in-hospital congestive heart-failure (P = 0.02) in the normal sizing group. There was a trend toward more moderate to severe aortic regurgitation (AR) in the normal sizing group (P = 0.07). Conclusions Despite a higher rate of PM implantation, oversizing based on this ratio reduces aortic leak with lower rates of post-procedural complications and a similar mid-term survival.
28-giu-2016
Derby, N., Sudre, A., Elquodeimat, I., Delhaye, C., Schurtzy, G., Bical, A., et al. (2016). Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures. JOURNAL OF GERIATRIC CARDIOLOGY, 13, 483-488 [10.11909/j.issn.1671-5411.2016.06.004].
File in questo prodotto:
File Dimensione Formato  
Derby - fattouch CT - Tavi.pdf

accesso aperto

Tipologia: Versione Editoriale
Dimensione 357.59 kB
Formato Adobe PDF
357.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/211977
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact