Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into three groups: normal, moderate and severe oversizing; depending on the ratio between the prosthesis area and the annulus area indexed and measured on MSCT. Main endpoint was mid-term mortality and secondary endpoints were the Valve Academic Research Consortium (VARC-2) endpoints. Results Two hundred and sixty eight patients had a MSCT and underwent TAVI procedure, with mainly Corevalve®. While all-cause and cardiovascular mortality rates were similar in all groups, post-procedural new pacemaker (PM) implantation rate was significantly higher in the severe oversizing group (P = 0.03), while we observed more in-hospital congestive heart-failure (P = 0.02) in the normal sizing group. There was a trend toward more moderate to severe aortic regurgitation (AR) in the normal sizing group (P = 0.07). Conclusions Despite a higher rate of PM implantation, oversizing based on this ratio reduces aortic leak with lower rates of post-procedural complications and a similar mid-term survival.
Derby N, S.A. (2016). Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures. JOURNAL OF GERIATRIC CARDIOLOGY, 13, 483-488.
Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures
FATTOUCH, Khalil;
2016-01-01
Abstract
Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into three groups: normal, moderate and severe oversizing; depending on the ratio between the prosthesis area and the annulus area indexed and measured on MSCT. Main endpoint was mid-term mortality and secondary endpoints were the Valve Academic Research Consortium (VARC-2) endpoints. Results Two hundred and sixty eight patients had a MSCT and underwent TAVI procedure, with mainly Corevalve®. While all-cause and cardiovascular mortality rates were similar in all groups, post-procedural new pacemaker (PM) implantation rate was significantly higher in the severe oversizing group (P = 0.03), while we observed more in-hospital congestive heart-failure (P = 0.02) in the normal sizing group. There was a trend toward more moderate to severe aortic regurgitation (AR) in the normal sizing group (P = 0.07). Conclusions Despite a higher rate of PM implantation, oversizing based on this ratio reduces aortic leak with lower rates of post-procedural complications and a similar mid-term survival.File | Dimensione | Formato | |
---|---|---|---|
Derby - fattouch CT - Tavi.pdf
accesso aperto
Dimensione
357.59 kB
Formato
Adobe PDF
|
357.59 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.