This paper presents the design of an electromagnetic interference (EMI) filter for a low-voltage high-current induction-motor drives supplied by dc power grids. In order to effectively design the EMI filter, a suitable common-mode/differential-mode (CM/DM) separation technique has been used. Due to the high operating currents, the software-based separation technique using time-domain measurements has been applied. The proposed technique allows the CM and DM sections of the EMI filter to be properly selected in a more economical way, i.e., without the need of a dedicated hardware or costly radio frequency (RF) instrumentation. The design has been done according to a power-density criterion. The effectiveness of the proposed CM/DM separation technique and the EMI filter features/performance has been assessed by experimental tests, carried out with an 1.1-kW pulsewidth modulation (PWM) inverter-fed induction-motor drive, supplied by a 48-V dc power grid.
Ala, G., Giaconia, G.C., Giglia, G., Di Piazza, M., Vitale, G. (2016). Design and Performance Evaluation of a High Power-Density EMI Filter for PWM Inverter-Fed Induction-Motor Drives. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 52(3), 2397-2404 [10.1109/TIA.2016.2518129].
Design and Performance Evaluation of a High Power-Density EMI Filter for PWM Inverter-Fed Induction-Motor Drives
ALA, Guido
;GIACONIA, Giuseppe Costantino
;Giglia, Graziella
;
2016-01-01
Abstract
This paper presents the design of an electromagnetic interference (EMI) filter for a low-voltage high-current induction-motor drives supplied by dc power grids. In order to effectively design the EMI filter, a suitable common-mode/differential-mode (CM/DM) separation technique has been used. Due to the high operating currents, the software-based separation technique using time-domain measurements has been applied. The proposed technique allows the CM and DM sections of the EMI filter to be properly selected in a more economical way, i.e., without the need of a dedicated hardware or costly radio frequency (RF) instrumentation. The design has been done according to a power-density criterion. The effectiveness of the proposed CM/DM separation technique and the EMI filter features/performance has been assessed by experimental tests, carried out with an 1.1-kW pulsewidth modulation (PWM) inverter-fed induction-motor drive, supplied by a 48-V dc power grid.File | Dimensione | Formato | |
---|---|---|---|
Final_manuscript_revised.pdf
accesso aperto
Descrizione: Articolo
Tipologia:
Post-print
Dimensione
871.84 kB
Formato
Adobe PDF
|
871.84 kB | Adobe PDF | Visualizza/Apri |
Design and Performance Evaluation of a High.pdf
Solo gestori archvio
Descrizione: Articolo principale
Tipologia:
Versione Editoriale
Dimensione
2.36 MB
Formato
Adobe PDF
|
2.36 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.