OBJECTIVES Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The end-points that were analysed included maximal aortic transverse diameter, perioperative mortality and morbidity, survival, freedom from reinterventions and aortic valve function during follow-up. The maximal aneurysm transverse diameter was analysed based on contrast-enhanced computed tomography (CTA) or magnetic resonance (MR) performed preoperatively, and during the follow-up. RESULTS The off-pump WT was used in 33 cases with no perioperative mortality. The median radiological follow-up was 33.47 (range: 1-106) months. Overall, the WT achieved a 30% diameter reduction. The mean preoperative and postoperative ascending aortic transverse diameter was 5.5 cm [standard deviation (SD): 0.6] and 3.7 cm (SD: 0.30), respectively (P = 0.001). In addition, CTA or MR follow-up showed stable diameters at the level of the aortic root and the distal ascending aorta. No death occurred during the follow-up. At 5 years, the estimated freedom rate from reinterventions of the aortic root and ascending aorta was 94%. CONCLUSIONS This series shows that the WT with a polypropylene/polyester mesh allows safe off-pump treatment of patients with iAA. Mid- and long-term results are promising. This technique could be an attractive alternative, especially for patients unfit for aortic surgery with CPB and cardioplegia.

Pecoraro, F., Shingaki, M., Steuer, J., Chaykovska, L., Rancic, Z., Weber, A., et al. (2016). Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 23(2), 286-291 [10.1093/icvts/ivw103].

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable

PECORARO, Felice;
2016-01-01

Abstract

OBJECTIVES Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The end-points that were analysed included maximal aortic transverse diameter, perioperative mortality and morbidity, survival, freedom from reinterventions and aortic valve function during follow-up. The maximal aneurysm transverse diameter was analysed based on contrast-enhanced computed tomography (CTA) or magnetic resonance (MR) performed preoperatively, and during the follow-up. RESULTS The off-pump WT was used in 33 cases with no perioperative mortality. The median radiological follow-up was 33.47 (range: 1-106) months. Overall, the WT achieved a 30% diameter reduction. The mean preoperative and postoperative ascending aortic transverse diameter was 5.5 cm [standard deviation (SD): 0.6] and 3.7 cm (SD: 0.30), respectively (P = 0.001). In addition, CTA or MR follow-up showed stable diameters at the level of the aortic root and the distal ascending aorta. No death occurred during the follow-up. At 5 years, the estimated freedom rate from reinterventions of the aortic root and ascending aorta was 94%. CONCLUSIONS This series shows that the WT with a polypropylene/polyester mesh allows safe off-pump treatment of patients with iAA. Mid- and long-term results are promising. This technique could be an attractive alternative, especially for patients unfit for aortic surgery with CPB and cardioplegia.
2016
Settore MED/22 - Chirurgia Vascolare
Pecoraro, F., Shingaki, M., Steuer, J., Chaykovska, L., Rancic, Z., Weber, A., et al. (2016). Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 23(2), 286-291 [10.1093/icvts/ivw103].
File in questo prodotto:
File Dimensione Formato  
68_2016_ICVTS_WRAPPINGOnly.pdf

accesso aperto

Dimensione 618.27 kB
Formato Adobe PDF
618.27 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/191200
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact