Functional Near InfraRed Spectroscopy (fNIRS) is an imaging technique mainly devoted to human brain monitoring. It is used as a non-invasive technique, in medical field, in order to measure the oxygen concentration of blood. This because the relatively good transparency of biological materials in the near infrared allows sufficient photon transmission through tissues. Within the so-called fNIRS range (650-900 nm), the main absorbers are blood chromophores, in particular the oxygenated and deoxygenated haemoglobin (HbO2 and Hb, respectively). When two or more wavelengths are used, changes of such chromophores can be computed by employing the modified Beer-Lambert law, thus providing important information about the brain activity. The main hardware novelty consists in the employment of Silicon PhotoMultiplier (SiPM) showing different advantages towards PhotoMultiplier Tubes, Avalanche PhotoDiodes, PIN or Single Photon Avalanche photodiodes. SiPMs are ideal candidates for CW-fNIRS applications and, furthermore, they could potentially increase the spatial resolution.

Agrò, D., Canicattì, R., Pinto, M., Adamo, G., Parisi, A., Stivala, S., et al. (2015). Brain Monitoring Via an Innovative CW-FNIRS System. In Proceedings of Convegno Italiano delle Tecnologie Fotoniche.

Brain Monitoring Via an Innovative CW-FNIRS System

ADAMO, Gabriele;PARISI, Antonino;STIVALA, Salvatore;GIACONIA, Giuseppe Costantino;BUSACCA, Alessandro
2015-01-01

Abstract

Functional Near InfraRed Spectroscopy (fNIRS) is an imaging technique mainly devoted to human brain monitoring. It is used as a non-invasive technique, in medical field, in order to measure the oxygen concentration of blood. This because the relatively good transparency of biological materials in the near infrared allows sufficient photon transmission through tissues. Within the so-called fNIRS range (650-900 nm), the main absorbers are blood chromophores, in particular the oxygenated and deoxygenated haemoglobin (HbO2 and Hb, respectively). When two or more wavelengths are used, changes of such chromophores can be computed by employing the modified Beer-Lambert law, thus providing important information about the brain activity. The main hardware novelty consists in the employment of Silicon PhotoMultiplier (SiPM) showing different advantages towards PhotoMultiplier Tubes, Avalanche PhotoDiodes, PIN or Single Photon Avalanche photodiodes. SiPMs are ideal candidates for CW-fNIRS applications and, furthermore, they could potentially increase the spatial resolution.
mag-2015
Fotonica 2015
Torino
6 - 8 maggio 2015
17
2015
2015
00
Agrò, D., Canicattì, R., Pinto, M., Adamo, G., Parisi, A., Stivala, S., et al. (2015). Brain Monitoring Via an Innovative CW-FNIRS System. In Proceedings of Convegno Italiano delle Tecnologie Fotoniche.
Proceedings (atti dei congressi)
Agrò, D.; Canicattì, R.; Pinto, M.; Adamo, G.; Parisi, A.; Stivala, S.; Giaconia, C.; Busacca, A.
File in questo prodotto:
File Dimensione Formato  
Fotonica 2015 - fNIRS.pdf

Solo gestori archvio

Dimensione 252.94 kB
Formato Adobe PDF
252.94 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/154756
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact