Objective. An important artifact corrupting Magnetic Resonance Images is the rf inhomogeneity, also called bias artifact. This anomaly produces an abnormal illumination fluctuation on the image, due to variations of the device magnetic field. This artifact is particularly strong on images acquired with a device specialized on upper and lower limbs due to their coil configuration. A method based on homomorphic filtering aimed to suppress this artifact was proposed by Guillemaud. This filter has two faults: it doesnt provide an indication about the cutoff frequency (cf) and introduces another illumination artifact on the edges of the foreground. This work is an improvement to this method because it resolves both problems. Methods. The experimental setup has been performed on knee images obtained by 5 volunteers and acquired through an Artoscan device using the following parameters: Spin Echo sequence, Repetition time: 980 ms, Echo time: 26 ms, Slice thickness: 4 mm, Flip Angle: 90. Results. Two specialists in orthoptics evaluated the results of the proposed approach by examining the restored images and validating the results produced by the filter. A quantitative evaluation has been performed on a manually segmented restored image using the coefficient of variation (cv) measure. Conclusions. Following the specialists qualitative evaluation, the illuminance of upper and lower peripheral zones results to be enhanced; a loose of contrast can be noted only in few cases. The Bias image exhibits an artifact focused usually on the central part of the foreground. The quantitative evaluation based on cv shows that this index is lowered for all the segmented regions with respect to the original value. The method is automatic and doesnt require any hypothesis on the tissues. A manual version of the algorithm can be also implemented allowing the physician to choose the preferred cf. In this case the value selected by the method can be considered as a default value.

E ARDIZZONE, R PIRRONE, GAMBINO O (2006). ILLUMINATION CORRECTION ON MR IMAGES. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 20, 6, 391-398 [10.1007/s10877-006-9040-1].

ILLUMINATION CORRECTION ON MR IMAGES

ARDIZZONE, Edoardo;PIRRONE, Roberto;GAMBINO, Orazio
2006-01-01

Abstract

Objective. An important artifact corrupting Magnetic Resonance Images is the rf inhomogeneity, also called bias artifact. This anomaly produces an abnormal illumination fluctuation on the image, due to variations of the device magnetic field. This artifact is particularly strong on images acquired with a device specialized on upper and lower limbs due to their coil configuration. A method based on homomorphic filtering aimed to suppress this artifact was proposed by Guillemaud. This filter has two faults: it doesnt provide an indication about the cutoff frequency (cf) and introduces another illumination artifact on the edges of the foreground. This work is an improvement to this method because it resolves both problems. Methods. The experimental setup has been performed on knee images obtained by 5 volunteers and acquired through an Artoscan device using the following parameters: Spin Echo sequence, Repetition time: 980 ms, Echo time: 26 ms, Slice thickness: 4 mm, Flip Angle: 90. Results. Two specialists in orthoptics evaluated the results of the proposed approach by examining the restored images and validating the results produced by the filter. A quantitative evaluation has been performed on a manually segmented restored image using the coefficient of variation (cv) measure. Conclusions. Following the specialists qualitative evaluation, the illuminance of upper and lower peripheral zones results to be enhanced; a loose of contrast can be noted only in few cases. The Bias image exhibits an artifact focused usually on the central part of the foreground. The quantitative evaluation based on cv shows that this index is lowered for all the segmented regions with respect to the original value. The method is automatic and doesnt require any hypothesis on the tissues. A manual version of the algorithm can be also implemented allowing the physician to choose the preferred cf. In this case the value selected by the method can be considered as a default value.
2006
E ARDIZZONE, R PIRRONE, GAMBINO O (2006). ILLUMINATION CORRECTION ON MR IMAGES. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 20, 6, 391-398 [10.1007/s10877-006-9040-1].
File in questo prodotto:
File Dimensione Formato  
illuminatio_correction_on_MR_Images.pdf

Solo gestori archvio

Descrizione: Copia per gli autori
Dimensione 527.18 kB
Formato Adobe PDF
527.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/15181
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact