ATHENA+ is a space mission proposal for the next ESA L2-L3 slot. One of the focal plane instruments is the X-ray integral field unit (X-IFU) working in the energy range 0.3-10 keV. It is a multi-array based on TES detectors aimed at characterizing faint or diffuse sources (e.g. WHIM or galaxy outskirt). The X-IFU will be able to achieve the required sensitivity if a low background is guaranteed. The studies performed by GEANT4 simulations depict a scenario where the use of an active anticoincidence (AC) is mandatory to reduce the background expected in L2 orbit down to the goal level of 0.005 cts cm s keV. This is possible using a cryogenic anticoincidence (CryoAC) detector placed within a proper optimized environment surrounding the X-IFU. We propose a 2 2 array of microcalorimeter detectors made by silicon absorber (each of about 1 cm and 300 m thick) and sensed by an Ir TES. In order to better understand the involved physics and optimize the performance, we have produced several samples featured by different absorber areas, TES size, and QPs Al collectors. Here we will discuss, as a review, the obtained results and the related impact to the final detector design.

Macculi, C., Piro, L., Colasanti, L., Lotti, S., Natalucci, L., Bagliani, D., et al. (2014). The Cryogenic AntiCoincidence Detector Project for ATHENA+: An Overview Up to the Present Status. JOURNAL OF LOW TEMPERATURE PHYSICS, Volume 176, Issue 5-6(Volume: 176 Issue: 5-6), 1022-1032 [10.1007/s10909-014-1150-4].

The Cryogenic AntiCoincidence Detector Project for ATHENA+: An Overview Up to the Present Status

BARBERA, Marco;
2014-01-01

Abstract

ATHENA+ is a space mission proposal for the next ESA L2-L3 slot. One of the focal plane instruments is the X-ray integral field unit (X-IFU) working in the energy range 0.3-10 keV. It is a multi-array based on TES detectors aimed at characterizing faint or diffuse sources (e.g. WHIM or galaxy outskirt). The X-IFU will be able to achieve the required sensitivity if a low background is guaranteed. The studies performed by GEANT4 simulations depict a scenario where the use of an active anticoincidence (AC) is mandatory to reduce the background expected in L2 orbit down to the goal level of 0.005 cts cm s keV. This is possible using a cryogenic anticoincidence (CryoAC) detector placed within a proper optimized environment surrounding the X-IFU. We propose a 2 2 array of microcalorimeter detectors made by silicon absorber (each of about 1 cm and 300 m thick) and sensed by an Ir TES. In order to better understand the involved physics and optimize the performance, we have produced several samples featured by different absorber areas, TES size, and QPs Al collectors. Here we will discuss, as a review, the obtained results and the related impact to the final detector design.
2014
Settore FIS/05 - Astronomia E Astrofisica
Macculi, C., Piro, L., Colasanti, L., Lotti, S., Natalucci, L., Bagliani, D., et al. (2014). The Cryogenic AntiCoincidence Detector Project for ATHENA+: An Overview Up to the Present Status. JOURNAL OF LOW TEMPERATURE PHYSICS, Volume 176, Issue 5-6(Volume: 176 Issue: 5-6), 1022-1032 [10.1007/s10909-014-1150-4].
File in questo prodotto:
File Dimensione Formato  
2014_Macculi_et_al_10909-014-1150-4.pdf

accesso aperto

Descrizione: Main article
Dimensione 1.26 MB
Formato Adobe PDF
1.26 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/100401
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact