This paper presents a method aimed to noise removal in MRI (Magnetic Resonance Imaging). We propose an improvement of Perona and Malik's anisotropic diffusion filter. In our schema, the diffusion equation of the filter has been modified to take into account the edges direction, This allows the filter to blur uniform areas, while it better preserves the edges. Both quantitative and qualitative evaluation is presented and the results are compared with other methods.
Ardizzone, E., Pirrone, R., Gallea, R., Gambino, O. (2008). Noise Filtering Using Edge-Driven Adaptive Anisotropic Diffusion. In IEEE International Symposium on Computer-Based Medical Systems (pp.29-34). Los Alamitos, CA : IEEE Computer Society [10.1109/CBMS.2008.31].
Noise Filtering Using Edge-Driven Adaptive Anisotropic Diffusion
ARDIZZONE, Edoardo;PIRRONE, Roberto;GALLEA, Roberto;GAMBINO, Orazio
2008-01-01
Abstract
This paper presents a method aimed to noise removal in MRI (Magnetic Resonance Imaging). We propose an improvement of Perona and Malik's anisotropic diffusion filter. In our schema, the diffusion equation of the filter has been modified to take into account the edges direction, This allows the filter to blur uniform areas, while it better preserves the edges. Both quantitative and qualitative evaluation is presented and the results are compared with other methods.File | Dimensione | Formato | |
---|---|---|---|
CBMS 2008 published.pdf
Solo gestori archvio
Descrizione: Articolo principale
Dimensione
1.26 MB
Formato
Adobe PDF
|
1.26 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
CBMS 2008 front cover.pdf
Solo gestori archvio
Descrizione: Copertina atti
Dimensione
250.3 kB
Formato
Adobe PDF
|
250.3 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
CBMS 2008 TOC.pdf
Solo gestori archvio
Descrizione: Indice atti
Dimensione
139.56 kB
Formato
Adobe PDF
|
139.56 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.