This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.

Cataliotti, A., Cosentino, V., Lipari, A., Nuccio, S. (2008). An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters. In Proceeding of I²MTC 2008, IEEE International Instrumentation and Measurement Technology Conference (pp.1269-1273) [10.1109/IMTC.2008.4547237].

An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters

CATALIOTTI, Antonio;COSENTINO, Valentina;LIPARI, Alessandro;NUCCIO, Salvatore
2008-01-01

Abstract

This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Settore ING-INF/07 - Misure Elettriche E Elettroniche
mag-2008
2008 IEEE International Instrumentation and Measurement Technology Conference, I2MTC
Victoria, Vancouver Island, Canada
May 12–15, 2008
2008
5
http://ieeexplore.ieee.org/document/4547237/
Cataliotti, A., Cosentino, V., Lipari, A., Nuccio, S. (2008). An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters. In Proceeding of I²MTC 2008, IEEE International Instrumentation and Measurement Technology Conference (pp.1269-1273) [10.1109/IMTC.2008.4547237].
Proceedings (atti dei congressi)
Cataliotti, A; Cosentino, V; Lipari, A; Nuccio, S
File in questo prodotto:
File Dimensione Formato  
I2MTC2008_A harmonic test condition.pdf

Solo gestori archvio

Descrizione: Articolo
Dimensione 892.24 kB
Formato Adobe PDF
892.24 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/6254
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact