Magnetic Resonance images are often characterized by irregularly displaced luminance fluctuations that are called bias artifact. This disturb is due to a drop in signal intensity caused by the distance between imaged sample and receiver coil. An original approach to bias removal in Magnetic Resonance images is presented, which is based on the use of Gabor filter to extract the artifact. The proposed technique restores the image using a correction model, which is derived from the attenuation of signal diffusion across the tissues. No hypotheses are made about the structure of the tissues under investigation and the used MR spectrum. The approach is presented in detail, and extensive experimental results are reported along with a comparison with other popular techniques for bias removal.

E ARDIZZONE, R PIRRONE, M MASTRELLA, GAMBINO O (2007). A Gabor-based Technique for Bias Removal in MR images. In Proc. of 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBC 2007 (pp.1314-1317). IEEE Press [10.1109/IEMBS.2007.4352539].

A Gabor-based Technique for Bias Removal in MR images

ARDIZZONE, Edoardo;PIRRONE, Roberto;GAMBINO, Orazio
2007-01-01

Abstract

Magnetic Resonance images are often characterized by irregularly displaced luminance fluctuations that are called bias artifact. This disturb is due to a drop in signal intensity caused by the distance between imaged sample and receiver coil. An original approach to bias removal in Magnetic Resonance images is presented, which is based on the use of Gabor filter to extract the artifact. The proposed technique restores the image using a correction model, which is derived from the attenuation of signal diffusion across the tissues. No hypotheses are made about the structure of the tissues under investigation and the used MR spectrum. The approach is presented in detail, and extensive experimental results are reported along with a comparison with other popular techniques for bias removal.
Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazioni
2007
Engineering in Medicine and Biology Conference (EMBC 2007)
Lione
23/08/2007
29
2007
4
CD-ROM
Lyon, France
E ARDIZZONE, R PIRRONE, M MASTRELLA, GAMBINO O (2007). A Gabor-based Technique for Bias Removal in MR images. In Proc. of 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBC 2007 (pp.1314-1317). IEEE Press [10.1109/IEMBS.2007.4352539].
Proceedings (atti dei congressi)
E ARDIZZONE; R PIRRONE; M MASTRELLA; GAMBINO O
File in questo prodotto:
File Dimensione Formato  
Start.pdf

Solo gestori archvio

Descrizione: copertina
Dimensione 470.88 kB
Formato Adobe PDF
470.88 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
04352539.pdf

Solo gestori archvio

Descrizione: articolo
Dimensione 954.67 kB
Formato Adobe PDF
954.67 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
indice.pdf

Solo gestori archvio

Descrizione: indice
Dimensione 782.21 kB
Formato Adobe PDF
782.21 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10447/5782
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact